Steven from Garden City, NY
Parts Used:
WP338906
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Dryer worked but did not heat
Followed troubleshooting steps. Checked thermal fuse (shorted)- OK. Checked igniter (about 70 ohms) - OK. checked flame sensor - (open) BAD (should read shorted). This part is normally shorted then opens when the igniter gets hot causing it to open and thus turns on the gas flow. An open flame sensor does not permit the igniter to turn on.