DV331AERXAA Samsung Dryer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Cody from Jonesboro, AR
- Parts Used:
- WP35001191, WP35001087
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Dryer wouldn't start.
I verified that the thermistor was bad by testing the resistance. My manual said it should be 10K ohms at 78F. I was reading over 30K ohms. This is what caused the thermostat to blow, as the thermistor was telling the dryer the air temp was a good 30 degrees cooler than it actually was. You can also verify the thermostat is bad by checking it for continuity. I removed the screws on the top-back of the dryer and slid the top back to reveal the screws holding on the control panel. I removed those and popped off the control panel. It required a good bit of force. I then removed the four screws holding the front piece on and removed it by pulling it slightly towards me and up. The parts are located on the bottom right. They were underneath a black plastic flap on my dryer. I removed the cables and the took both parts out with a screwdriver. I replaced them with the new ones (they should only fit in the right slot) and reattached the cables. From there, reassemble in reverse of the disassembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jamesii from MILAN, IL
- Parts Used:
- WP35001191
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
The dryer would run and heat up then turn off and alarm before the clothes were dry. The display would read tO.
After reading other posts, I learned that "tO" meant that the thermistor was open. Also, I read that this part would bench test with a multimeter correctly but could still malfunction in the dryer. FIRST UNPLUG DRYER. After checking all of the exhaust ducting including inside the dryer for any blockages that could result in an overheating problem I decided to order a new thermistor. To replace thermistor: First, there are two screws at the rear top that you remove and the top tilts up and comes off. There are four screws on the top front that removes the front control panel. Next remove the screws at the top of the dryer, two screws in recesses behind the door and tilt front forward while unplugging the door switch. Lift and remove front with door attached. Remove screws from exhaust duct and slide down and out. Thoroughly clean inside of duct and fan blades. Clean out any other lint build up. Locate thermistor to the right of duct, unplug and remove two screws. Replace with new part and reassemble while not forgetting to plug the door switch back in. At the rear of dryer, remove screws around exhaust duct and remove. Dryer will have to be slid away from wall about three feet to remove duct from inside dryer. Clean thoroughly and check/clean and check for blockages in ducting from dryer to outdoors. Re assemble making sure rear duct engages the front ducting properly.Plug dryer back in and enjoy.
Was this instruction helpful to you?
Thank you for voting!