- Customer:
- John from MUSKOGEE, OK
- Parts Used:
- 279834
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Wrench set
The heat would go off after a few minutes
Removed the screws on the dryer vent and the back of the dryer top. Then I raised up the top panel and removed the screws that held the front panel on. I removed the front panel to access the coils. I replaced the coils and then the front and top panel and screws. All went well. The dryer is working properly now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from STOW, OH
- Parts Used:
- 279834
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Dryer would not heat
Followed directions from Youtube video
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Melissa from FOWLER, OH
- Parts Used:
- 279834
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set
Dryer would not heat.
Diagnose that the circuit is functioning up to the igniter. This is done by removing the peep hole cover on the bottom front panel, turn the dryer on and watch for a glowing igniter. My dryer would still ignite the first time because the coils would not show an "open" until they heated up. So if you see the igniter glow it is most likely your coils are bad. Remove two screws from lint trap area on top of dryer. Pry up on top panel at the two clips. Panel is on hinges, so flip it out of the way or just brace it with something enough to keep it off the front panel. Remove the two bolts from inside top corners of the front panel. Use a small punch or screw driver to push in on the tab to release the doors electrical connector. Pull straight up on front panel to remove it from bottom clips. The gas valve is very easy to get to without removing the drum. If needed for inspection or cleaning, just pull back on the belt tensioner to remove the belt from the motor and then pull the drum out. Or just use a stubby phillips screw driver to remove the bracket from the top of the ignition coils. Use a very small flat head screw driver to lift the locking tab on each electrical connector while removing. Remove the coils and place new ones in very same position (note the tab or key way of the coils faces up and are defined in the bracket). Re-assemble all parts making sure connections are tight and drum is correctly mounted. Note: if you remove the drum, return the belt back, in a loop, through the tensioner. This part hurt my head for a moment because I did not pay attention. Also a good idea to vacuum the debris and lint while your in there! As always check to make sure the exhaust pipe is clear. Have fun!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wayne from BAKERSFIELD, CA
- Parts Used:
- 279834
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers, Wrench (Adjustable)
Dryer not drying- gas valve coil resistance measured 'Open'.
Unplug dryer first! Remove toe panel with 1/4" nut driver on each lower corner. Gas assembly will be on the right immediately below right of drum. Use a short Phillips screwdriver to break loose two screws retaining hold-down plate on gas valve coils. I used an adjustable wrench to turn the screwdriver on screws which are not easy to apply torque to. Each coil will easily slip off stem. Disconnect catch on plug with very small flat tip screwdriver for each coil, then pull off connector. Ensure the 3-terminal coil goes to the front and the 2-terminal to the rear. Note aligning tips on coils which correspond to holes in hold down plate. Reassemble in reverse order except for toe panel. Plug in dryer and verify gas valve operation and flame presence. Replace toe panel.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bill from SAINT CHARLES, MO
- Parts Used:
- 279834
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Dryer was drying the cloths very, very slowly
I follow the instructions provided on the your web site, the instructions were very easy to follow and to the point. In all it easier than expected. your information regarding the probability that the indicated part will solve the problem are great! That gave me a good feeling about ordering the part from you. Thanks for your help.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- william from SAN DIEGO, CA
- Parts Used:
- 279834
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers, Socket set, Wrench (Adjustable)
Dryer would stop heating after 5-10 minutes.
Unplug power. Remove the lint filter and remove the 2 screws under the lint cover lid. Use flathead screw driver to pop off the top of the dryer housing. The clips are located at the front two corners.Just wedge and lift up to unclip. Remove two hex head screws on each side disconnecting the side housing from the front housing. Disconnect the wiring harness at the front top right side if you are facing dryer. Lift up on the front housing to unclip the bottom of housing. Just lift up and pull housing face toward you at an angle. The circular dryer piece where clothes go into will be loose but still attached. It will sag down a little. Then on bottom left side unscrew two screws to remove the 2 coils. You will need a stubby phillips screw driver about 1.5" long and you will need to lift up on the dryer circular piece out of the way a little. Once you remove the crews, remove the clip holding the two coils. Remove the wiring from the coils. 1 coil has two leads and one has 3. Replace one at a time just in case your model is slightly different. Be sure to install the coil with the little knobby part up and in alignment for when you reinstall the clip/ bracket that holds it in place. Replace the coils and install the racket/ clip with 2 screws. Reinstall the wires. Reinstalling the front face of dryer housing is a little tricky because you have to slide the bottom back onto the clips while holding the circular dryer part up. Then push the front housing up against the circular piece so they are aligned and fit. While holding it, screw the two hex screws on each side. Then reconnect harness and snap the top housing back onto the front face housing clips. Reinstall the two screws at the lint trap. Reinstall the lint trap and plug back in. The dryer is now fixed if that was your problem. Its a fairly simply job once you start doing it. Good luck.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dennis from LINDENHURST, NY
- Parts Used:
- 279834
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Screw drivers
Dryer not getting clothes dry
Dryer was getting hot at start of cycle and would drop out flame and then cycle flame every 45 sec to 1 min. Pulled of panel to observe this and thought it was a heat sensor problem. Went online and people were saying a coil could be bad. I took coils out and tested them and they tested good but I bought new ones anyway as I figured they were going out of range as they heated up, This proved correct as dryer works .
Was this instruction helpful to you?
Thank you for voting!
Dryer heats once when turned on and then you have to wait 15 minutes to restart it
Well, had I read more of the reviews on this website, I would have learned that my problem was the valve coils. Instead, I assumed it was the igniter, so I ordered and installed a new igniter to no avail. I was about to just go buy a new dryer at Home Depot and spend $600, but I had to try again so I read more reviews on this website and began measuring resistances across the valve coils and discovered I had a bad one. I ordered both just to be safe, and installed them and quickly enjoyed my first uninterrupted dryer cycle in over a year (for over a year, I had been stopping and restarting my dryer about 10 times for each cycle). So THANKS for this website and to all the home technicians who posted symptoms, resistances, and how-to-do-its to help me get this done. It was an empowering experience to fix this and have bookmarked this website for any future appliance fixes. It's a great website with all its schematics and postings.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Susan from Glendale, CA
- Parts Used:
- 279834
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers, Socket set
Dryer flame would light then would not ignite again
I used a socket to take of the front cover. I used a screwdriver to remove the two screws that held the coils in place. Replaced the coils and put everything backs together. Piece of cake!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Plainfield, IN
- Parts Used:
- 279834
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Gas dryer would not ignite.
I removed two wires from the coil valves. Then I removed two screws from the bracket that holds the coil valves in place. I removed the faulty coil valves and replaced them with the new ones. Put the bracket back on and replaced the two screws and wires. It took almost 5 minutes. The dryer is like new once again.
Was this instruction helpful to you?
Thank you for voting!
igniter wold come on for a second then shut off no flame
removed the two screws that hold the coils in place pulled the coils terminal connections off removed and replaced with new coils reattached quick disconnect terminals dryer now works better than when it was new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jon from RIVERSIDE, CA
- Parts Used:
- 279834
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Igniter works, valves open, gas Ignitestation then shuts off
All the videos said the same thing. If the Igniter works and the gas ignites bit shuts off soon after that, then the coils are bad. I bought the coils and it didn't fix the problem. My bad, I should have put my meter on it to test it before I bought the part and waited a week to get the coils. Now I'm in the process of illuminating the sensors. I will figure it out. Make sure you use the meter. It will save you the headaches.
Was this instruction helpful to you?
Thank you for voting!
dryer not heating( after replacing the high temp. thermostat
i removed the door and front panel then removed the two screws holding the coil bracket,disconnected the two wires on coils,set new coils in place and reversed the above process
Was this instruction helpful to you?
Thank you for voting!
no flame on burner after initial ignite
I shut off the power supply (pulled plug) . Opened the front access door on bottom of dryer, The two coils sat on top of burner unit, with a plate and 2 Phillip head screws securing them. .I used a small set of pliers to pull the terminals off, then I used a short Phillip head screw driver due to the proximity of the dryer drum close by. The coils slide off, slide the new ones on, re secure the plate with screws, reconnect the terminals, plug in the power cord and away you are for a fraction of the cost.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeff from Livermore, CA
- Parts Used:
- 279834
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
No Heat from dyer
Well, this is quite easy really. I found the problem after plucking and chucking a few parts but it was finally the igniter that was the problem. After taking the front section panel off to access the components, take the time to unscrew the igniter and see if it is cracked. That is what happened to my unit. I replaced to the new M series coils as well but the issue was the igniter. Look very carefully for a crack, the one on my unit was very small. You can ohm it out with a meter and if it reads open it is cracked.
Was this instruction helpful to you?
Thank you for voting!