jeff from SPARTA, NJ
Parts Used:
279834
Difficulty Level:
Very Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Dryer not getting hot
Open top of dryer, then remove front. Coils on lower left. Unplug and replace coils. Vacuum loose lint from bottom of dryer. Replace front then top of dryer. Test run. All good !
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from MUSKOGEE, OK
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Wrench set
The heat would go off after a few minutes
Removed the screws on the dryer vent and the back of the dryer top. Then I raised up the top panel and removed the screws that held the front panel on. I removed the front panel to access the coils. I replaced the coils and then the front and top panel and screws. All went well. The dryer is working properly now.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from SAINT CHARLES, MO
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Dryer was drying the cloths very, very slowly
I follow the instructions provided on the your web site, the instructions were very easy to follow and to the point. In all it easier than expected. your information regarding the probability that the indicated part will solve the problem are great! That gave me a good feeling about ordering the part from you. Thanks for your help.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Arthur from VALLEJO, CA
Parts Used:
WP338906
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Socket set
would not heat
I started by changing the part that had the highest percentage to solve this problem , the top three didn't work , the fourth part, the disposable thermostat, and the last one that could be done from the front worked.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alfred from DELMAR, DE
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
My gas dryer was drying intermittantly. The gas valve wasn't opening when the igniter was firing up.
rts came quickly & I got started. First, I unplugged the dryer and pulled it away from the wall about a foot. this was done so the top would have clearance when it was lifted up. Next, I removed the lint trap and then took the two screws under the lint trap door out. Then you use a screwdriver(flat blade) to release the top of the dryer. The release points are about 1-2 inches from the edge of dryer. Next pull the wire connector apart so the front can be removed. The connector is on the right side, front corner, facing the dryer. There are two hexhead screws near the top on both sides. Remove the and the front will come apart as you lift it slightly. Then you disengage the tub belt. Once this is done the tub can be lifted out and set aside/ take care to remember each things position as you take it apart, so you will not get confused when you reassemble. Now the solinoid assembley is easy to get to. Use a phillips screw driver and remove the two screws that retain the bracket that holds the solinoids in place.. Lift the bracket and remove one solinoid at a time. Pull the wire from it and plug the new, like solinoid to the wire and put it back in place. then do the other one. set the bracket back over the new kit and replace the screws to the bracket. Set the tub back in, rethread the belt to the drive wheel. Next put the front back on making sure the bottom part slips into the two sides of the dryer.Replace the hexhead screws on each side; plug the wire connector together. Now , pull the lid down into position and press into place. Replace the lint trap screws and replace the lint trap. Plug dryer up and we are done. Repossition the dryer to its original place. It really was not a hard job at all. Thank-you Susan for your help and expertise.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from LINDENHURST, NY
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Dryer not getting clothes dry
Dryer was getting hot at start of cycle and would drop out flame and then cycle flame every 45 sec to 1 min. Pulled of panel to observe this and thought it was a heat sensor problem. Went online and people were saying a coil could be bad. I took coils out and tested them and they tested good but I bought new ones anyway as I figured they were going out of range as they heated up, This proved correct as dryer works .
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from WARWICK, RI
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers, Socket set
clothes were not drying in expected timeframe
1st replaced limit thermostat because it tested bad; this did not resolve the problem. Initial burn was successful. Heating element would heat but burner would not ignite for subsequent burns unless allowed to cool down for 10 minutes or more. Coils tested at correct values, but a u-tube video said that was not always an indication of a flawless coil set. It was either the coils or the burner itself. Burner would not have been a justifiable expense even though it came with new coil set, so tried the coil set, and it resolved the problem.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
marlon from KINGMAN, IN
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
dryer was not heating
popped top up with flat screw-took out 4 screws (2 screws-1/4" nut driver - 2 phillips screws on bracket that holds coils in place) unplugged 2 wire lugs (1 three wire & 1 two wire) changed out bad coils screws back in-plugged wires back in -popped top back down .done
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from Springfiled, OH
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Dryer would light for 30 secs. & flame would go out
Checked ignitor it was working ok, disconnected 3 pronged coil and disconnected 2 pronged coil using multi tester checked continuity on both coils both tested 0,with help of operator ordered M Series new style coil kit. When parts arrived installed coils attached wire harnesses installed bracket and 2 screws that secures coils. Started dryer it worked and stayed working who needs the Maytag Repair Man probably saved about 200.00 between service call and markup on coils. Thanks Virtual Repairman
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Muskegon, MI
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
no flame on burner after initial ignite
I shut off the power supply (pulled plug) . Opened the front access door on bottom of dryer, The two coils sat on top of burner unit, with a plate and 2 Phillip head screws securing them. .I used a small set of pliers to pull the terminals off, then I used a short Phillip head screw driver due to the proximity of the dryer drum close by. The coils slide off, slide the new ones on, re secure the plate with screws, reconnect the terminals, plug in the power cord and away you are for a fraction of the cost.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeff from Livermore, CA
Parts Used:
279834
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
No Heat from dyer
Well, this is quite easy really. I found the problem after plucking and chucking a few parts but it was finally the igniter that was the problem. After taking the front section panel off to access the components, take the time to unscrew the igniter and see if it is cracked. That is what happened to my unit. I replaced to the new M series coils as well but the issue was the igniter. Look very carefully for a crack, the one on my unit was very small. You can ohm it out with a meter and if it reads open it is cracked.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jon from RIVERSIDE, CA
Parts Used:
279834
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers
Igniter works, valves open, gas Ignitestation then shuts off
All the videos said the same thing. If the Igniter works and the gas ignites bit shuts off soon after that, then the coils are bad. I bought the coils and it didn't fix the problem. My bad, I should have put my meter on it to test it before I bought the part and waited a week to get the coils. Now I'm in the process of illuminating the sensors. I will figure it out. Make sure you use the meter. It will save you the headaches.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
William from Plainfield, IN
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Gas dryer would not ignite.
I removed two wires from the coil valves. Then I removed two screws from the bracket that holds the coil valves in place. I removed the faulty coil valves and replaced them with the new ones. Put the bracket back on and replaced the two screws and wires. It took almost 5 minutes. The dryer is like new once again.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
shaun from mount laurel, NJ
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
igniter wold come on for a second then shut off no flame
removed the two screws that hold the coils in place pulled the coils terminal connections off removed and replaced with new coils reattached quick disconnect terminals dryer now works better than when it was new
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Susan from Glendale, CA
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
Dryer flame would light then would not ignite again
I used a socket to take of the front cover. I used a screwdriver to remove the two screws that held the coils in place. Replaced the coils and put everything backs together. Piece of cake!