Customer:
Michael from Royal Palm Beach, FL
Parts Used:
WP338906
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Clothes were not getting dry enought
Unplugged dryer from power source, used putty knife to release latches that hold top on, tilted the top out of the way, unplugged door lite, located the radiant switch, removed 1 screw,then undid 2 wires & lifted out switch. Reversed procedure plugged in dryer....wa la had dried a large load of clothes, took 1/3 the time to dry clothes at last. Thanks "PartSelect"
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steven from Oak Lawn, IL
Parts Used:
WP338906
Difficulty Level:
Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers, Socket set
No heat
I feel like I have a new dryer now. I replace 3 of the 4 main components using parts select. Not only did they ship next day, but the tutorial videos with Steven were right on the money and self explanative.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lee from St. Louis, MO
Parts Used:
WP338906
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Dryer not staying hot
Ordered thermal fuse and cycling thermostat
Was this instruction helpful to you?
Thank you for voting!
Customer:
Rodney from Zimmerman, MN
Parts Used:
WP338906
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Our dryer would not ignite, so I figured it was the radiant flame sensor. Well, I out that in and still nothing. I found out that the Tube Burner was also burned off on the flame end, by the igniter. I also ordered that part. installed it, and it works beautifully.
On the Amana dryer, I had to remove the top panel. then the front panel to access the burner assembly. I also had to remove the gas pipe coming to the burner, because I replaced the tube burner assembly at the same time. There is only one screw that holds that back end of that gas pipe. The thermal flame sensor is on the left side of the burning chamber, with only one small Phillips head screw. just remove the 2 wires, keeping track of which terminal they belong. Just twist the sensor out of the small slot, and out it comes. The tube burner assembly is fastened with 2 screws. The entire burner assembly comes out in one piece, but be real careful not to bang the igniter when removing it. The coil assembly has 2 wires, which you cannot get wrong, because one has 2 prongs, the other has 3 wires.The local repair shop wanted 90 bucks per hour, plus parts, and I installed both the burner tube and radiant flame sensor for around $80.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Neil from Harwich, MA
Parts Used:
WP338906
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Flame when out to fast. Dryer did not get hot enough.
Unplugged electrical cord to dryer. removed the front cover 2 screws on the bottom. Lifted front cover off. Unplugged the 2 wires going to the old flame sensor. Used nut driver to remove 1 screw holding the flame sensor in. Removed old sensor replaced with new one. Reattached the 2 wires back on to the new flame sensor. Tested. Flame stayed on longer! Dryer works great dryer is 20 years old and still running like new now. Part was the exact match I needed.
Was this instruction helpful to you?
Thank you for voting!