- Kevin from Simi Valley, CA
- Parts Used:
- WE12X10014
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Broken belt
I didn't know what was wrong at first, only that the dryer would not start. I bought it used so had no fear of taking it apart to diagnose. Found the broken belt inside, ordered a replacement, installed the new belt, then crossed my fingers. Was pleasantly surprised that was all that was wrong and that for less than $20, including shipping, a few hours of my time, and a little help from YouTube videos the dryer is working again!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Randy from FREMONT, CA
- Parts Used:
- WE4X344
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Pliers, Screw drivers
Dryer would not start and the smell of an electrical part burning.
What to do if you have a load of wet laundry at 23:00, the dryer won’t start, and you have no spare start switch.
Removed rear access panel and discovered the wire from terminal #2 (goes to heater coils) on the start switch had melted and disconnected. The start switch showed signs of overheating but not melted. Removed the switch and found the switch’s actuator button was jammed in the ‘in’ position (dryer won't start). The switch was a friendly one in that it was possible to disassemble it. Most switches today are molded/glued together, but this one could be pried apart. The contacts inside were still in fair condition and, after dressing them, the switch was reassembled. The actuator button had a burr that was filed off and the switch action worked fine. All of the 1/4" male QC contacts on the switch were cleaned with a wire brush. The burned wire was cut back about 6” and a new piece of 14ga wire was spliced in with a wire nut. A new 1/4” QC terminal was crimped to the wire and all wires were re-attached to the switch.
This fix would probably last for a long time to come, but I bought a new switch and installed it and will keep the old switch as a backup.
p.s. The load of laundry was dry by 02:00.
Removed rear access panel and discovered the wire from terminal #2 (goes to heater coils) on the start switch had melted and disconnected. The start switch showed signs of overheating but not melted. Removed the switch and found the switch’s actuator button was jammed in the ‘in’ position (dryer won't start). The switch was a friendly one in that it was possible to disassemble it. Most switches today are molded/glued together, but this one could be pried apart. The contacts inside were still in fair condition and, after dressing them, the switch was reassembled. The actuator button had a burr that was filed off and the switch action worked fine. All of the 1/4" male QC contacts on the switch were cleaned with a wire brush. The burned wire was cut back about 6” and a new piece of 14ga wire was spliced in with a wire nut. A new 1/4” QC terminal was crimped to the wire and all wires were re-attached to the switch.
This fix would probably last for a long time to come, but I bought a new switch and installed it and will keep the old switch as a backup.
p.s. The load of laundry was dry by 02:00.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- james from chicago, IL
- Parts Used:
- WE12X10014
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Screw drivers, Wrench set
original equipment belt-drive broke
disassembled chassis of dryer, unbolted top, lifted top to expose drum. bolted top back on. resumed repair next morning. unbolted top. lifted drum (it moved up and down about 1 inch) and got new belt around it. rebolted top down. tipped dryer to its back. unbolted and removed panel at bottom, exposing drive motor and tensioner spring. positioned belt around drive motor spindle and tensioner spring. replaced panel. reconnected dryer to electricity. reconnected gas using new flexible connector.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Kristin from Bellevue, WA
- Parts Used:
- WE17X10010
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Pliers, Screw drivers, Socket set
The main symptom was a burning smell that got on the clothes and the dryer was somewhat louder than it had been.
Researching on the web I thought the trouble might be lint buildup or trouble w/ one of the parts involved in spinning the drum. However I cleaned out all the lint and replaced the belt and idler pulley and this didn't improve the smell (drum bearing was fine). I then concluded the trouble was the motor. Running the motor w/o the drum in place confirmed this was where the noise/smell was coming from. Replacing the motor was fiddly--I had to remove the clip holding the motor (pried the top w/ a screwdriver), wires (made a diagram so as to put back in same order, they were hard to get off--a pliers did the job), clamps holding the motor on the duct, the motor mount, the duct, the fan. Putting all this back together took a while (not hard just fiddly). Tested the motor w/out the drum in place and it sounded fine. Put the drum and back/front/top panels back and the dryer runs fine now. All parts came quickly and exactly matched the parts in my 1993 Hotpoint dryer. As others have said the pulley kit is not needed--these are included w/ the motor. BTW I am a 53-year-old lady. Thanks to all who took the time to write up their experiences--big help!!