- Customer:
- Gary from CHRISMAN, IL
- Parts Used:
- WE14X215
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers, Wrench set
No flame. Igniter came on but no gas.
Opened up dryer for access to all components and tested. All checked good. Put back together and tested and igniter came on but no flame. Purchased two new coils and tested again. No flame. Purchased complete valve assembly and replaced old one. Tested again and viola, success! TY PartSelect for exact replacement part.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- William from Deerfield, IL
- Parts Used:
- WE14X215
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench set
No heat from dryer. Diagnosed by others as the Gas Valve
Watched tecnician (I paid) as he diagnosed the problem. Four screws take of the top and front. Clothes drum slides out. Access to valve is good. Valve attaches to feed via compression fitting. Male end of fitting on unit is moved to new unit via allen wrench. Drive belt is re attached around drum and over idler easily. Part cost $90.00 shipp0ed to me. Technician asked $375.00 for this repair. Access the parts via placing the model number on Google Search.