DDG8580RAL General Electric Dryer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Richard from Appleton, ME
- Parts Used:
- 5303931775
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Dryer runs but produces no heat
Unplug the unit. The top of the dryer is held down by 2 simple friction pins. By lifting the dryer top above it's front door panel the top will swing up. Prop the top up so you can reach down the front panel. There are 2 Phillips screws about 6 inches down on the dryers front panel. Remove the 2 screws, tip the front panel toward you it will slip off the dryer drum. Remove the 2 push on wires attached to the door switch. Gently lift the front panel off the 2 hinge points at the bottom and set it aside. The parts that your going to replace are the 2 solenoids on the burner assembly. The burner assembly is located on the lower left side of the dryer. Remove the 2 Philips screws that "clamp" the solenoids in place. Pull the 3 & 2 wire friction connectors off the solenoids. Lift the clamp off the top of the solenoids. Pick the 2 solenoids up off the valve assemble. Put the 2 new solenoids on the valve assembly push the wires back on, put the clamp back on and resemble the dryer. *Note: just to make a quick check on the continuity of the solenoids. I suspended the dryer drum so it could rotate without damaging it, put my clamp on amp probe on the 120v line to the solenoids the 3 wire one was good the 2 wire one was open.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Plymouth, MA
- Parts Used:
- WE05X20431
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Burned out interior dryer drum light
Tried to replace with home-store bought 6w light. Looked the same, fit into socket, but didn't work. Actually exploded when I turned it on! Be sure to use OEM part like this one. Worked perfectly!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Santa Barbara, CA
- Parts Used:
- WE4X197
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Dryer would not start
I checked the power (OK) and removed the four screws that held the timer/controls (upper panels) cover. This revealed a schematic for the dryer that enabled me to determine the door swich was probably the culprit. I pried out the old switch and, sure enough, it was always open (checked with multi-meter). I found the replacement switch easily using the dryer model number and "door switch" search string. Ordered Sunday night, the part came on Tuesday and took 2 minutes to install (no tools needed).
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dorothy from Kingston, OK
- Parts Used:
- WE1M1011
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
door would not stay closed
It was super easy, done in 5 less than 5 min. Thanks Parts Select. Parts Select made it easy to find the replacement part by posting pictures. Thanks
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dane from Visalia, CA
- Parts Used:
- WE4X444
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Dryer worked, but there was no heat to dry the load.
Removed from lower panel. Just popped it open
with a screw driver.
Unplugged dryer and shut off gas by the gas shut-off valve.
Loacated the gas igniter element and removed it
by pulling up. It is only healed in place by a metel
like a clothes pin.
Using caution slid new unit down and into the pinching device.
Plugged in power cord and the gas.
Turned the unit on and it worked !!!
This was worth the try. Better than buying a new
dryer with the economy the way it is now.
with a screw driver.
Unplugged dryer and shut off gas by the gas shut-off valve.
Loacated the gas igniter element and removed it
by pulling up. It is only healed in place by a metel
like a clothes pin.
Using caution slid new unit down and into the pinching device.
Plugged in power cord and the gas.
Turned the unit on and it worked !!!
This was worth the try. Better than buying a new
dryer with the economy the way it is now.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Christine from Auburn Hills, MI
- Parts Used:
- WE18X26
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
The lint filter on my 28-year-old dryer had holes in the screening.
I removed the old lint filter and put the new one in! Grateful to find this item for my "antique" dryer.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- STAN from UPPER ARLNGTN, OH
- Parts Used:
- WE1M1011
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Plastic housing for the door latch mounted in the chassis of the dryer was damaged so the section of the latch in the door wouldn't align.
This kept the interlock open and shut off the dryer when the door swung open The broken latch was popped out using a flat blade screwdriver and the replacement snapped into place by hand. Good as new!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Tyler from Story City, IA
- Parts Used:
- 5303931775
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
My dryer would light but when it called for more heat it would not light.
lifted the top panel, there were 2 screws to remove the front panel, then the coils were right there on the bottom left side. a screw or two hold the coils inplace. Then just unplug the old coils and plug in to the new coils.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Barry from Dunellen, NJ
- Parts Used:
- WE18X26
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken lint trap
Just changed lint trap by removing old one and replacing new one.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Domenic from Livingston, NJ
- Parts Used:
- WE18X26
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Lint Filter had holes in it. req. replacement,
Simple - took out the defective filter and replaced with the purchased part. The hardest part was figuring out the right lint filter. The extensive info on PART SELECT was very helpful.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Aaron from Kerhonkson, NY
- Parts Used:
- 5303931775
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
clothes not drying in one cycle
remove top cover, remove front of dryer, unscrew two #2 screws from gas valve coil hol down bracket. replace coils. reassemble dryer.. works great.. had already replaced the thermostate and flame sensor.. didn't change anything.. the coil set did the trick..
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- greg from abilene, TX
- Parts Used:
- WE25M40
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
old bearing completley gone; shaft eating through race making a horrible noise when running
pull top and front of dryer (6 screws), take belt off drum and pull drum out the front of dryer. Take the three star head screws out of stainless heat vent inside of drum and take old bearing housing out of back wall of dryer housing. Pretty much self evident putting everything back in, some trouble installing new bearing housing in back wall of dryer, screws are hard to turn in by hand (new hole). Vacum inside of dryer housing, install everything the way in came out, , plug it in and WA-LA.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- David from Parker, CO
- Parts Used:
- WE4X791
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Timer was not shutting down, running continously, and with no heat regulation
Removed the 2 hex head scres holding the front panel assembly to the main unit. Then removed the screws holding the back sheet metal panel to the control panel. Pull back on the control panel to disengage the slotted flanges from the main dryer body. Rotate the control panel forward to expose the wiring and guts of the panel. Remove the holding screw for the timer assembly and place it out of the way. DO NOT remove any of the wire connectors from the old timer assembly yet. Rmove the control knob from the old timer assembly using a flat head screwdriver to pry it from the control rod. Place the knob on te new timer assembly and screw the completed assembly to the control panel. Now remove the bridging wire terminal and attach to the new timer in the same position as the old one. Now one at a time remove the wire connectors from the old timer and attach to the corresponding terminals on the new assembly. Reattach the sheet metal back cover with the screws and then replace the entire panel assembly back into the main body slots. Replace the hex head scews and reattach the power which you disconnected prior to doing anything else. Clean up the dust bunnies as long as you are back there. Tell the wife that this was a very complicated repair and worthy of a beer and some golf course time.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Port Charlotte, FL
- Parts Used:
- WE4X197
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Door switch wore out
It was very easy. Pop out old, connect new wires and done! Can't say enough as to how fast and easy getting the part from this company was. Ordered the part later in the day one night and on the second day the part was there. Outstanding service.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jack from Huntingdon, PA
- Parts Used:
- 5303931775
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
Dryer wasn't heating
Determined that the coil on the gas valve wasn't pulling in to ignite. Using an ohmmeter, I determined the coil was open. The coil was removed by pulling off the wire connecter and removing the two phillips screws holding the bracket over the two coils. The coil then slides out. I slid the new coil into place, replaced the bracket and two screws and reconnected the wire connector. It worked immediately. The actual repair only took 15 minutes. The bulk of the time was spent tracking down which part had failed.
Was this instruction helpful to you?
Thank you for voting!