DV306LEW Amana Dryer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Robert from Waxhaw, NC
- Parts Used:
- WPW10222771
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Heating element not working
IMPORTANT!!! Unplug the unit first!! 1 - Remove two screws on the back of the top of the unit. Pull back a little on the top to release it from underneath the control unit on the front of the dryer (the piece with the dial and buttons). 2 - Remove the four screws from the control unit. They are located at the top of the dryer. Pop off the control unit - don't worry about breaking any wires as there are none. 3 - Remove the front of the dryer by removing the four screws that are NOT used for the door and door latch. I had also removed the door latch and door but I don't think it is necessary to remove them. The front will swing out from the bottom where you can unhook it and remove it. 4 - the heating element is located on the front of the unit, bottom right. Either draw a diagram of the wires or take a picture of them with your cell phone. Smart phones are great for this as you can zoom the picture if necessary. Remove the wires (they just push on but it may take some effort to get them off). It's either one or two of the wires that are not part of the wiring harness and they go from one part of the element to another so don't get excited if these wires fall down - you haven't done anything wrong, they are just loose. The one screw in the front holds the element in (the back of the unit just rests in that hole). Remove the screw and pull the unit out. Put the new element in, hook up the wires before positioning the element. Put the screw back in that holds the element and put the rest of the dryer back in the reverse order.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Cody from Jonesboro, AR
- Parts Used:
- WP35001191, WP35001087
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Dryer wouldn't start.
I verified that the thermistor was bad by testing the resistance. My manual said it should be 10K ohms at 78F. I was reading over 30K ohms. This is what caused the thermostat to blow, as the thermistor was telling the dryer the air temp was a good 30 degrees cooler than it actually was. You can also verify the thermostat is bad by checking it for continuity. I removed the screws on the top-back of the dryer and slid the top back to reveal the screws holding on the control panel. I removed those and popped off the control panel. It required a good bit of force. I then removed the four screws holding the front piece on and removed it by pulling it slightly towards me and up. The parts are located on the bottom right. They were underneath a black plastic flap on my dryer. I removed the cables and the took both parts out with a screwdriver. I replaced them with the new ones (they should only fit in the right slot) and reattached the cables. From there, reassemble in reverse of the disassembly.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Beatriz from Sharonville, OH
- Parts Used:
- WP35001193, WP35001191
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
the thermistor was open circuit
I change the Thermistor 3 bracket and worked well for 10 minutes and the thermistor is broken again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from Kearney, MO
- Parts Used:
- WP35001193, WP35001092
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
No heat
*Disconnect power cord before performing this task...(1) Remove the two screws holding top.(2) Remove four screws holding control module, tilt forward, pull up and unlatch. Place module on top, out of the way (still connected by wires). (3) Open dryer door, remove two screws holding lint trap assembly, close door. (4) Remove four screws on top of front cover, disconnect door light wire, tilt front cover forward, lift up from catch at bottom and remove. (5) Disconnect moisture sensor connection on bottom right for easier access to duct assembly. (6) Remove three screws holding duct assembly support bracket in place, raise duct assembly six inches to allow the bracket to be tilted toward rear and lifted out of the way. (7) Disconnect Red and Blue wires from front of duct assembly and pull assembly carefully from the rear of the unit and out the front paying attention to the wires still connected. (8) Remove wires connected to the thermostat and thermistor. (9) Remove screws holding in both units and replace with new components. (10) Reverse process and test. *note* if the unit appears to heat but clothing still wet, make sure moisture sensor was connected (I must have forgot and got to go back in to check, ooops). Regardless, this is an easy task. Could be intimidating at first but after the part has been accessed twice its no big deal and can be done over a lunch break.
Was this instruction helpful to you?
Thank you for voting!