Models > ADG20L2H > Instructions

ADG20L2H Admiral Dryer - Instructions

Jump to:

All Instructions for the ADG20L2H
91 - 105 of 447
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Lou from Weymouth, MA
Parts Used:
LA-1053
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Dryer had no power. Internal light was out too.
I followed the "How to" video on your web site. Most importantly, I cleaned the entire filter area which probably caused the problem as your instructions recommended. I will do that annually going forward. I would recommend your service to anyone.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamye from Suffolk, VA
Parts Used:
LA-1053
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Screw drivers
Dryer just stopped working all together
first I went online and took a look at the schematic and realized that two items can shut the complete unit down and would be easy to check. First I checked the door switch with a multimeter then the high limit non-resettable thermostat. The contacts on the thermostat were open which told me it was bad. Went online to www.partselect.com and found the part really easily. came in when they said it would and it was a perfect match to the original (part numbers on the side and eveything). Make sure you correct the problem that caused the unit to overheat in the first place. IN my case the dryer air passages were full of lint. After a good cleaning put it all back together and it worked better than it has in years.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
mark from santa clara, CA
Parts Used:
LA-1053
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Wrench (Adjustable)
Thermal shut off shut off.
Replaced the thermal shut off and the thermistor located on the heating element bracket.
Easy to diagnose and to replace- not totally accessable but not that bad either. Cleaned out lint obstruction causing the problem.
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve from WASHINGTON, IA
Parts Used:
WP31001344, 25-7957
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Cracks in the pulley
I loosened the belt removed the drum, removed the push nut and cracked pulley and replaced both,old push nut was a little stubborn but finally got it off.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from MISHICOT, WI
Parts Used:
279834
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
Heat not staying on.
Checked out the coil seemed ok. So I replaced the radiant flame sensor. No change. Then I replaced the High limit sensor still the heat was not staying on. I read some were in the troubleshooting guide that the coil can test good, but can still malfunction. So that was it new coil fix it, works like a new Dryer again.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
larry from OLNEY, TX
Parts Used:
LA-1053
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
dryer stopped running, no power
I watched the video tape
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Russell from LEESBURG, FL
Parts Used:
LA-1053
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
elec.dryer would not start
i followed part select instructions that probable cause was either thermal fuse or high limit thermostat.put ohm meter across both & saw thermal fuse(has pink dot on it) part 53-1182 was open.ordered thermal fuse replacement kit. part#LA-1053. the problem i had was after reaching down the side of heating housing removing the bracket with the thermal fuse,replacing & reconnecting it i had a hard time reinstalling the bracket,very tight space & i don't have very big hands.finally got the fuse in it's hole in the bracket & slid & jammed the bracket into the side of the mounting housing & it stayed secure.dryer started
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Randall from Ripley, TN
Parts Used:
LA-1053
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
nothing worked no light when door was open
I just removed 1 screw that held the safety thermostat in and replaced it. Then I removed the long screw that holds the heating element and the high limit fuse in place. Replaced the fuse, cleaned out the lint duct area. Closed the dryer lid and pluged it in, it worked fine.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Christopher from Brick, NJ
Parts Used:
LA-1053
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Dryer would not turn on
Lifted top from dryer and fuses were in the back of drum just below heating coil. Used nut driver to remove heating coil to gain access to fuses and replaced them. Process was quick and easy. Diagram from this site made locating fuses elementary!

P.S. I have no certified experience in appliance repair.This was my first time ever and dryer works perfect.
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
james from HURON, OH
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
dryer not heating( after replacing the high temp. thermostat
i removed the door and front panel then removed the two screws holding the coil bracket,disconnected the two wires on coils,set new coils in place and reversed the above process
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Leslie from Idaho Falls, ID
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The gas would not ignite.
First we removed the front panel then the door. Removed the old coils and put in the new coils, oh yeah don't forget to disconnect the power supply first. Sure enough that was all it took and it runs great. You really can fix your own appliance if you take the time to do some research.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jeremy from Westerville, OH
Parts Used:
LA-1053
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
High Limit fuse thermostat blew, dryer quit working.
I ordered the part. This is now my third order. It appears that every 10-12 months this happens. I opened the top of the dryer by using a flat head screw driver to push in two clips. The clips are along the front edge of the lid about two inches in from each side. Push in with the screw driver while pulling up the lid. Once the lid is open (of course the plug is pulled) I locate the heat coil. Above the heat coil is the the thermostat, I replace that. Or maybe it is the over heat fuse, I forget. I then replace the sensor found along the side of the heat coil. Re-attach wires. Close lid. Plug back in and ready to go.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Muskegon, MI
Parts Used:
279834, 279834
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
no flame on burner after initial ignite
I shut off the power supply (pulled plug) . Opened the front access door on bottom of dryer, The two coils sat on top of burner unit, with a plate and 2 Phillip head screws securing them. .I used a small set of pliers to pull the terminals off, then I used a short Phillip head screw driver due to the proximity of the dryer drum close by. The coils slide off, slide the new ones on, re secure the plate with screws, reconnect the terminals, plug in the power cord and away you are for a fraction of the cost.
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jon from RIVERSIDE, CA
Parts Used:
279834
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers, Screw drivers
Igniter works, valves open, gas Ignitestation then shuts off
All the videos said the same thing. If the Igniter works and the gas ignites bit shuts off soon after that, then the coils are bad. I bought the coils and it didn't fix the problem. My bad, I should have put my meter on it to test it before I bought the part and waited a week to get the coils. Now I'm in the process of illuminating the sensors. I will figure it out. Make sure you use the meter. It will save you the headaches.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kevin from ROUND LAKE, IL
Parts Used:
WP31001556
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Wrench (Adjustable)
Gas Dryer runs but never heats up
Went to your website for information on how to open the cabinet and clues of what could be wrong. I used a putty knife to open top. i
removed two screws holding the front panel then lifted the panel up off of two clips holding it in place. Removed door switch from panel and set panel aside. I turned the dryer on and noticed that the igniter never turned on but the drum turned CCW. I then unplugged the electric cord from the wall and turned off the gas at the supply valve behind dryer.
I removed 3 connectors (1 from igniter, 2 from gas valve coils). Mark the gas valve flare nut and tube with a marker so you know how much to tighten it on reassembly.
I used two adjustable wrenches to remove gas line from gas valve.
Then removed one screw holding gas valve assembly in place.
Removed gas valve assembly from dryer. I took a nut driver to remove screw holding the igniter to the assembly. I used a meter to check bad igniter and it was open. I checked new igniter and it read 88 ohms.
Caution: never touch the igniter heating surface with your bear hands because you will shorten its life. Clean dryer lint from front panel and cabinet. Now reverse these steps for reassembly.
Thank you for the video on how to open the cabinet and the ideas for what could be the problem. The dryer was 2004/2005 model so about 14 years old.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ADG20L2H
91 - 105 of 447