Surface element with Limiter - 6" - 1200W went out
First, I turned the circuit breaker off to the range. Then, I pulled the range out so that I could get to the screws which held the glass top in place. They were located on the sides of the range. I had to remove the trim pieces on the sides to get to the forward screws. Once that was done, I lifted the glass top, unplugged the wire harness, flpped it over on a protected surface. I noted the numbers on the old coil where the clips held it in place and put the clips on the new coil in the same place. The old wires just clipped on to the new coil exactly as they clipped on to the old coil. I put it all back together and it works great! I am a 70 year old woman who did this all by myself. You young guys should have no problem.
Was this instruction helpful to you?
Thank you for voting!