Customer:
Robert from Warwick, RI
Parts Used:
4681A20172Q
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Noisy motor
Removed front, rear and side panel. matched up connector of old motor to new. unplugged old harness and plugged in new motor before, I installed it to see if it worked. Ran and sounded great. Took old motor off and replaced with new. All good.
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Chris from Doylestown, PA
Parts Used:
4681A20172Q
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set
Squealing fan motor outside unit minisplit
First let me say that I was searching for a fan motor for my Friedrich minisplit. Friedrich and their main parts supplier said the part is unavailable with no alternative part. I was searching by the condenser model number only ( MR36Y3J ) and found the exact same unit from LG. The parts diagrams were identical and Partselect had the exact part I needed. It fit perfectly and now not only is my unit quiet, I’m not forced to replace the whole mini split system. $200 and an hour of my time versus $8k.

The installation was a piece of cake, and I have never opened any hvac equipment previously. Disconnected power, opened it up, verified the part and replaced it after cleaning up the unit with a shop vac. A fan motor is not a complicated part but they come in specific sizes, duty cycles, wiring. It was literally a few screws to open the case, a fan blade bolt, and 3 bolts on the motor. The wire connection was exact and easy to route to the main logic board.

$7800 saved.
1 person found this instruction helpful.
Was this instruction helpful to you?