CRA107BU110 Frigidaire Air Conditioner - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Randy from Sumas, WA
- Parts Used:
- 5304476059
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers
Fan Blade Broken
I took all of the outer screws out and removed sheet metal cover. I had to unbolt fan motor from bottom of the unit. I moved the fan motor so I could remove the Fan Blade. Put new blade on and reversed the process. Works Fine.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Bobby from Monroe, NC
- Parts Used:
- 5304476183
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
No cooling. Sound of compressor not coming on
I took the air conditioner apart. Then, I turn the unit on. The ever-present sound of the compressor was not there. I jumped the compressor relay out, And it came on. I contacted PartSelect With the model number And told them I needed the power control board. Ingested few days I had the board and completed the repair in less than one hour. I rate this company at five star.
Was this instruction helpful to you?
Thank you for voting!