bad element control switch
1. Turn off power to range at circuit breaker
2. Remove grate
3 Remove control knobs
4, Remove two screws holding control panel
5. With wrench, remove locking nuts from control switches
6. Lift panel, exposing switches
7. With new switch in hand, unattach old switch one terminal at a time, attaching new switch exactly as old switch, terminal by terminal.
8. Replace everything in reverse order
9.Turn on power
2. Remove grate
3 Remove control knobs
4, Remove two screws holding control panel
5. With wrench, remove locking nuts from control switches
6. Lift panel, exposing switches
7. With new switch in hand, unattach old switch one terminal at a time, attaching new switch exactly as old switch, terminal by terminal.
8. Replace everything in reverse order
9.Turn on power
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Richard from Sacramento, CA
- Parts Used:
- A406
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Broken exhaust vent cover.
Just removed the broken vent cover.
Injected foaming sealant.
Pushed on the vent cover plate.
Screwed it in place.
More foaming sealant.
Clipped on the flapper and secured the cover.
Injected foaming sealant.
Pushed on the vent cover plate.
Screwed it in place.
More foaming sealant.
Clipped on the flapper and secured the cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Wade from CARMINE, TX
- Parts Used:
- 707704K
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Screw drivers
Motor bearing failure after 34 years.
Important: Down load the helpful assembly diagram for the fan motor and study it for a few minutes. It's very straight forward. Also a good idea is to remove the bottom panel which comes off easy before starting.
My only problem was removing the existing blower/fan wheel without damaging it once I had the assembly on the work bench. It was rusted on tight and managed to remove after a few tries using penetrating oil. The wheel is in stock and I'd suggest buying a new one along with the new motor if I had to do the job again.
Bottom line; the fan motor fit perfect but did have to re-use part of the old existing electric pig tail because the motor does not come with the factory type motor terminal connectors. By using three twist on wire connectors was back in business. The down draft vent works like new.
Wife is happy...
Wade
My only problem was removing the existing blower/fan wheel without damaging it once I had the assembly on the work bench. It was rusted on tight and managed to remove after a few tries using penetrating oil. The wheel is in stock and I'd suggest buying a new one along with the new motor if I had to do the job again.
Bottom line; the fan motor fit perfect but did have to re-use part of the old existing electric pig tail because the motor does not come with the factory type motor terminal connectors. By using three twist on wire connectors was back in business. The down draft vent works like new.
Wife is happy...
Wade
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Jacksonville, AL
- Parts Used:
- A405
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Didn't like the appearance of a cheap-looking dryer vent on an exposed area of my new house.
I enlarged the vent access hole from four (4) inches to five (5) inches to accomodate a larger pipe. I then purchased locally a 5" to 4" transition and installed it in the enlarged opening, and sealed the space with expanding foam for a bug-proof air-tight fit. On the inside of the house I attached a short length of 4" pipe to attach the dryer vent pipe. On the outside, in the place of the aluminum vent cap, I installed the 5" Jenn-Aire vent cover purchased from PartSelect.com. The new vent is large enough to completely cover the chiseled out masonry area, and the 5" outlet reduces air noise from the dryer, but best of all the new vent provides the high quality look I needed to match the brick of my new home.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from PICAYUNE, MS
- Parts Used:
- 192980GS
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
Dry rotted rubber
Put some dish soap on the rubber, push into the tank hole, slip 1x2 into the handle of the tank and over the new part and pry down pushing it into the hole. Took about 2 minutes.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Sulphur, OK
- Parts Used:
- A405
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Wall vent cap & damper were broken.
Attached spring to damper, placed on existing 5" duct and secured. Used screwdriver to attach vent cover to damper.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from RADFORD, VA
- Parts Used:
- 192980GS
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Pliers, Screw drivers
old valve dripped gas when opened on cold sub zero day
old valve easily pulled out with screwdriver and pliers
install difficult due to 40 degree cold temp and bushing didn't want to squeeze into fuel tank hole
install required lots of liquid soap on bushing, which popped into place by using upward prying pressure from 3"X24" plywood braced into under-shelf of gas tank
used same technique to insert valve upward into bushing
works great!
install difficult due to 40 degree cold temp and bushing didn't want to squeeze into fuel tank hole
install required lots of liquid soap on bushing, which popped into place by using upward prying pressure from 3"X24" plywood braced into under-shelf of gas tank
used same technique to insert valve upward into bushing
works great!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Robert from Shaker Hts, OH
- Parts Used:
- A405
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
broken vent cap
Unscrewed old cap, installed new
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- John from LEES SUMMIT, MO
- Parts Used:
- 192980GS
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers
major gas leak on my generator
popped out the old-----the bushing failed. replaced as per the included instructions
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brent from EAST LYME, CT
- Parts Used:
- A405
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
Install New Vent Cover
Installation was straight forward as the new vent cap was sized correctly for exhaust pipe (5 inch). Placed the mounting plate into the exhaust pipe and used 4 SS screws to anchor to house sheathing. The vent flapper was not flat, requiring that I carefully stress relieve it at 250 degrees and hold it flat while cooling to take warp out. Snapped it in place afterwards and then bolted on cover.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jim from Brewton, AL
- Parts Used:
- A406
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
old worn out wall vent cap.
removed old and replaced with new without difficulty.
Was this instruction helpful to you?
Thank you for voting!
bearing went out in blower motor
removed old motor from cooktop & motor housing & replaced w/ new motor & parts to install same. parts needed where screws & isolators (3).All went ok
Was this instruction helpful to you?
Thank you for voting!