Models
>
GNSF39A01
GNSF39A01 General Electric Water Softener
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for GNSF39A01
Viewing 1 of 1Keep searches simple, eg. "belt" or "pump".
In Stock
Order within the next 34 mins and your part ships today!
In Stock
Order within the next 34 mins and your part ships today!
In Stock
Order within the next 34 mins and your part ships today!
In Stock
Order within the next 34 mins and your part ships today!
In Stock
Order within the next 34 mins and your part ships today!
Special Order
Special Order
Special Order
Special Order
Special Order
On Order
Special Order
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Problems and Symptoms for GNSF39A01
Viewing 1 of 1Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- John from RICHMOND, TX
- Parts Used:
- WS15X10077
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
Using RustOut in the brine tank for years destroyed the seals and salt valve of the brine assembly. Easier to replace entire brine valve assembly.
Remove the top back lid/unlatch 2 clips. Unscrew the small brine tube nut (white) from left side of control unit. Cut the tube to remove nut from old tube with utility knife. Keep nut for use on new assembly. Not included. Remove brine well cover. Pull the tube out of the top and from behind resin tank and remove assembly from brine well
... Read more
. Discarded the old brine valve assembly. Removed the bit of old tube from the nut, w/ utility knife. Careful not to damage the old nut. Snake the new brine tube from front right side through the back of the resin tank to the old hole on the left. Follow the old path. Insert the new brine tube into the top section through the hole the old one came out of. Attached nut to new brine tube. Screw nut/new brine tube to the connector of control unit. Small fingers help. Adjust/slide the float assembly 6-8 inches inches above the valve, e.g. Styrofoam/Metal Weight slides up/down the white stalk. Re-inserted the brine assembly into the brine tank. Replace top. Manually regenerate to make sure new brine assembly is not leaking and filling the brine tank properly. Done.
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Ernesto from MIAMI, FL
- Parts Used:
- WS60X10004
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Wrench set
broken valve cli[p
It was very simple to replace the broken clip, the only problem was to figure out where is the position of the bypass valve to let water to go into the tank, the seal with the instruction in the valve is missed. Thanks, I am very happy with the GE water softening system
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Frank from Okemos, MI
- Parts Used:
- WS60X10004
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Would not recharge because metering turbine was jammed.
Followed diagnostic instructions in users' manual. Access to turbine requires disconnecting softener from water supply, so both brine valve clips must be removed. Not possible without breaking them. After that, the job was straight forward. Removed a small particle that was jamming the turbine, and reconnected. LESSON LEARNED: ORDE
... Read more
R BRINE VALVE CLIPS BEFORE STARTING REPAIR.
Read less
Was this instruction helpful to you?
Thank you for voting!