Models > GXSH45V00

GXSH45V00 General Electric Water Softener

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for GXSH45V00

Viewing 2 of 2

Manuals & Guides for GXSH45V00

Click to download
Keep searches simple, eg. "belt" or "pump".
In Stock
$8.35
Sold individually and used with water softeners.
In Stock
$10.94
For use with external, stand-alone water filters.
Special Order
Used in Water Filters.
On Order
On Order
Special Order
$14.70
For use with external, stand-alone water filters.
In Stock
In Stock
Used for Water Filters.
Special Order
$33.34
In Stock
Special Order
$474.34
In Stock

Questions and Answers

Be the first to ask our experts a question about this part!

Common Problems and Symptoms for GXSH45V00

Viewing 1 of 1
Touchpad does not respond
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
John from RICHMOND, TX
Parts Used:
WS15X10077
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Using RustOut in the brine tank for years destroyed the seals and salt valve of the brine assembly. Easier to replace entire brine valve assembly.
Remove the top back lid/unlatch 2 clips. Unscrew the small brine tube nut (white) from left side of control unit. Cut the tube to remove nut from old tube with utility knife. Keep nut for use on new assembly. Not included. Remove brine well cover. Pull the tube out of the top and from behind resin tank and remove assembly from brine well . Discarded the old brine valve assembly. Removed the bit of old tube from the nut, w/ utility knife. Careful not to damage the old nut. Snake the new brine tube from front right side through the back of the resin tank to the old hole on the left. Follow the old path. Insert the new brine tube into the top section through the hole the old one came out of. Attached nut to new brine tube. Screw nut/new brine tube to the connector of control unit. Small fingers help. Adjust/slide the float assembly 6-8 inches inches above the valve, e.g. Styrofoam/Metal Weight slides up/down the white stalk. Re-inserted the brine assembly into the brine tank. Replace top. Manually regenerate to make sure new brine assembly is not leaking and filling the brine tank properly. Done.
4 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dennis from LIBERTY, MO
Parts Used:
WS26X10030, WS60X10008
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
The unit was not measuring water as it went thru.had stuck turbin.
Very easy to put softener in bypass and release pressure by starting a regeneration cycle. Clips removed by hand with no force required. Separate bypass from softener. Removed old turbine and slid new turbine into unit. Reconnect bypass valve and install clips by hand. Return softener to service mode. Unit now shows gal / minute in screen .
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joong from otis, ME
Parts Used:
WS60X10011
Difficulty Level:
Easy
Total Repair Time:
More than 2 hours
Tools:
Pliers, Wrench (Adjustable)
OLD iron connection adaptor caused leaking
I replaced old rusty iron adaptors with new bronze adaptors.
No more leaking and finished replacing new GE water softner.

Thank you for quick delivery of plastic connectors.
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!