This is a genuine OEM 40-Watt replacement light bulb that is compatible with various types of appliances. It has a frosted glass bulb with a standard metal socket base, making it easy to screw and uns...
In Stock
Order within the next 12 hrs and your part ships today!
The defrost timer works on a predetermined schedule, to alternate between the cooling cycle and the defrost heater in your freezer. When the heating circuit is activated, it melts any ice that has for...
In Stock
Order within the next 12 hrs and your part ships today!
Door switch turns the light off when you close the door.
In Stock
Order within the next 12 hrs and your part ships today!
The bi-metal defrost thermostat is attached to the evaporator, and its purpose is to protect the evaporator from overheating when the defrost cycle is running. If there is frost building up in your fr...
In Stock
Order within the next 12 hrs and your part ships today!
$127.17
This kit includes ice bucket and water valve and fits Whirlpool models manufactured from 1993 to present.
In Stock
Order within the next 12 hrs and your part ships today!
This 18 ml bottle of white appliance touch-up paint is used to cover scratches or marks on your appliance. The white touch-up paint can be used on refrigerators, microwaves, ranges, clothes dryers, an...
In Stock
Order within the next 12 hrs and your part ships today!
$13.38
Sold individually.
In Stock
Order within the next 12 hrs and your part ships today!
$108.15
Sold individually.
In Stock
Order within the next 12 hrs and your part ships today!
$5.42
Sold individually.
In Stock
Order within the next 12 hrs and your part ships today!
The bulb is sold separately.
In Stock
Order within the next 12 hrs and your part ships today!
$49.37
Also known as retainer bar.
On Order
In Stock
Order within the next 12 hrs and your part ships today!

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Problems and Symptoms for NWT0002D02

Viewing 17 of 17
Light not working
Fixed by these parts
Fixing Fixing
How to fix it
Fridge too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Freezer not defrosting
Fixed by these parts
Fixing Fixing
How to fix it
Freezer section too warm
Fixed by these parts
Fixing Fixing
How to fix it
Leaking
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Will Not Start
Fixed by these parts
Fixing Fixing
How to fix it
Fridge and Freezer are too warm
Fixed by these parts
Fixing Fixing
How to fix it
Ice maker not making ice
Fixed by these parts
Fixing Fixing
How to fix it
Fridge too cold
Fixed by these parts
Fixing Fixing
How to fix it
Frost buildup
Fixed by these parts
Fixing Fixing
How to fix it
Freezer too cold
Fixed by these parts
Fixing Fixing
How to fix it
Fridge runs too long
Fixed by these parts
Fixing Fixing
How to fix it
Noisy
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Too warm
Fixed by these parts
Fixing Fixing
How to fix it
Door won’t open or close
Fixed by these parts
Fixing Fixing
How to fix it
Ice maker won’t dispense ice
Fixed by these parts
Fixing
How to fix it
Won’t start
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Cathy from Winter Park, FL
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is n ot functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
154 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clint from Rayville, MO
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
118 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LES from MADERA, CA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Defrost timer was faulty. Required a mild tap to restart
Trouble shot the electrical circuit per the electrical schematic and zeroed in when I noted the Defrost Timer circuit was open. When I tapped on the bottom of the timer it began functioning normally (for a few days). Ordered a new Defrost Timer Kit and along with the installation instruction, I watched the on-line video. It was very help ful!!
After installation was complete, I plugged the Refrigerator into the electrical outlet and.......nothing happened! Hmmm!

Removed the Defrost Time Kit and inspected it for any damage and found none. Then I placed a flathead screwdriver to the manual advance knob and slightly rotate the gear mechanism. I heard a distance "click”. I believe the Timer was in the ‘defrost’ mode when received.

I reinstalled the timer, verified the wiring connections and this time plugged the Refrigerator into the electrical outlet and ….. it worked!!!

I unplugged the refrigerator, finished the installation per the instructions, plugged the unit in and monitored it for a few hours (just in case). That was a week ago and the Refrigerator is working like new.

The instructions were written in a manner which required re-reading a few times as they could be a bit vague. The video was what really helped and I appreciate PartSelect adding it to the instructions.
66 of 72 people found this instruction helpful.
Was this instruction helpful to you?