Models > 10650212011 > Instructions

10650212011 Kenmore Refrigerator - Instructions

Jump to:

All Instructions for the 10650212011
1 - 15 of 884
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
BILL from BATESVILLE, MS
Parts Used:
W10823377, WP2196195, WP2180226, WP2162361
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Front Door Ice Wouldn't Work And Air Going Into Freezer
Thanks to the pictorial diagram, I was able to order correct parts. It was just a matter of removal of broken parts and replacing them. Ice maker now working and air is no longer getting into freezer which was freezing up ice maker. Thanks for timely delivery, now I am able to use ice dispenser, which I haven't used for long time. Thanks
492 of 592 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Norbert from Sugar Land, TX
Parts Used:
WP2182179, WPW10329686
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refigerator door was not closing all the way if not pushed shut.
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.
393 of 414 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Steve earney from Brooks, GA
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
inconsistent compressor and condensor fan operation
Compressor start relay would cycle several times before compressor would come on. Replaced start relay and defrost timer assy. Operated more consistently however not completely reliable. Ice would begin to melt. Noticed that if you would cycle the temperature control the compressor would start again and operate for several hours then not cycle again. Jumpered temp control and operation was continuous and reliable. Replaced cold control thermostat. Operation now normal. Suspect high resistance in switch caused start relay and timer contacts to arc. Small amount of carbon noticed under temp control...
305 of 320 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Josue from Jacksonville, NC
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Seven year old condenser fan was making noise when it was running.
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.
199 of 210 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from seaford, VA
Parts Used:
4388736
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Plastic bits dispensed from Ice Dispenser in Door
Removed Ice bin from Fridge

Removed all bolts on bin with nut driver...about six

Removed housing...be careful with spring on crusher/cube control rod

Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.

Removed plastic nut on end of auger shaft

Removed Ice crusher jaws and laid them out in the correct order

Removed Ice propeller and installed new part

Put back together in opposite order

Easy
202 of 238 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from Winter Park, FL
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
154 of 179 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Conrad from Tucson, AZ
Parts Used:
8201537
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Water Dispensor Tubing Had Become Brittle And Broke .
Removed the face plate. Removed a few screws and unpluged a few electrical connectors and pulled apart. Removed the holding bracket and clear tubing from door. Cut new tubing at an angle to push through conduit. Reinstalled new bracket and re-installed electrical connectors. Snapped face trim on and bleed air out of system. . Water ran great.
207 of 344 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
T.w. from Batesville, AR
Parts Used:
WP2182179, WPW10329686
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator Door quit closing on it's own......
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !
140 of 153 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Betty from Orinda, CA
Parts Used:
WP2188664, WP2188661
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Previous owners of the condo took the two drawers from the refrigerator
No repair, just slid the drawers in their places.
Since you had a diagram of the refrigerator parts, ordering the parts was easy and I was confident that the parts were the correct ones.
129 of 152 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from clarksville, TN
Parts Used:
WP2198202
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The compressor would shut down and not restart unless you tapped the temperature knob which i did for about 3 weeks before ordering this part
Was pretty simple just take the knobs off pull off the face plate remove a few screws and drop the whole shelf down. then a few more screws down the side to the back of the fridge. Pull the sensor wire out of some styrofoam and pull off the plastic coating and slide it over the new one and install it in reverse order from taking it out. Works great now and i have ice everyday :)
116 of 121 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
helen j from murrells inlet, SC
Parts Used:
W10823377
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
where ic e dispencer spring is held to door broke at mold
after ordering ice dispencer repair kit, and removing the outer parts found out that the problem was the ice dispencer door shell . this part is no longer available.It seems to me that if whirlpool wants to have return customers they have to stand behind the product. Well I made a L bracket and drilled a hole to to recieve the spring keeper and glued this to the housing and used a 3 1/12"finishing nail as the pin all works fine
123 of 142 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamie from Mitchell, SD
Parts Used:
WPW10190965
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker quit working
First I removed the three screws with a nut driver and then disconnected the wire plug from the old ice maker. I plugged in the new unit and re-installed the screws and instantly the unit started to work. I did have to adjust the water level on the unit ...just turn the small plastic knob (use a slotted screw driver) on the side of the unit counterclockwise to increase the water level (do not turn more than one full turn or you could damage the unit) . It works perfect and saved me lots of money!!
107 of 123 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Chesterfield, MO
Parts Used:
W10823377
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Warm Air Getting Into Freezer
Patience is a virtue. The kit really works. 1st, lift the front plate of the ice dispencer by placing a flat head screw driver into the two slots at the bottom of the panel. When the panel is lifted up slightly at the bottom, push up on the panel to remove it. Careful not to break panel and the wires attached. Next, remove the wiring panel by removing the two screws on left and right sides. Then, unplug the old black ice cover from the wiring panel (this is the heating plug that you will nolonger need). Next, remove the parts and replace them with the parts in the kit, noting where each part comes from, etc. All parts in the kit are necessary and should be used. Some of the replacements need trial and error. Patience will be important. Also needed is a person that loves to solve problems, especially because the kit does not come with instructions. But the kit definitely works!
109 of 132 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Antoni from vail, AZ
Parts Used:
4389144
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
evaporator fan stopped working
1) removed the face plate that runs 3/4 way up the back of the freezer side. a total of 8 screws. (6")
2) disconnected the three electrical connections.(30sec)
3) removed the fan of the the old evaporator fan motor (5sec)
3) removed the fan motor (1")
4) put in the new fan motor (1")
5) put on the old fan on the new fan motor(5sec)
6) reconnected the three electrical connections (30sec)
7) replaced the face plate on the back of the freezer (6")
Had re-frozen meat within 1 hour.
95 of 104 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Eddie from Gretna, LA
Parts Used:
WP2198202
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers, Socket set
Refrigerator was not cooling properly.
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "
73 of 76 people found this instruction helpful.
Was this instruction helpful to you?