Customer:
BILL from BATESVILLE, MS
Parts Used:
W10823377, WP2196195, WP2180226, WP2162361
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Front Door Ice Wouldn't Work And Air Going Into Freezer
Thanks to the pictorial diagram, I was able to order correct parts. It was just a matter of removal of broken parts and replacing them. Ice maker now working and air is no longer getting into freezer which was freezing up ice maker. Thanks for timely delivery, now I am able to use ice dispenser, which I haven't used for long time. Thanks
492 of 591 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Norbert from Sugar Land, TX
Parts Used:
WP2182179, WPW10329686
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Refigerator door was not closing all the way if not pushed shut.
Remove the top hinge cover. Removed the top hinge support. Lifted the door from the bottom support. Old door cams were worn completly flat. Replaced the lower door cam and closing cam use a little vasalene for lubricant on the cam surfaces. Placed the door back on the lower hinge support. Replaced the top hinge support. Door is closing great now.
Thanks for the quick part deliver.
393 of 414 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
garth from forest lake, MN
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
394 of 474 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Wolfeboro, NH
Parts Used:
W10408179
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set, Wrench (Adjustable)
When the remote water was turned on, water was pouring onto floor from rear of refrigerator
First I unplugged the fridge, then using the socket set I removed the cardboard shield from the lower rear of the refrigerator. I located the leaking water from a cracked solenoid water valve just inside the lower cavity directly behind the water intake line. Removing the valve was a snap - most of the valve plastic compression couplings unscrewed and came off. The metal compression fittings required an adjustable wrench and a pair of pliers to hold the solenoid unit steady. A couple of hex nuts kept the solenoid bolted to the refrigerator frame and came off easily with the socket. Two simple push-on electrical plugs came right off just by pulling on them. The new valve unit wasn't exactly like the original one. It had push-on instead of compression water fittings and the plugs were oriented differently. I recommend studying which water lines entered which port on the valve because I was a little unsure after I took the old one apart (whoops). After figuring out how to put it pack together, the push-on water fittings were even easier, and the unit was scewed back into place on the fridge frame. The electric plugs have different sized contacts so you can't mix them up. I put the cardboard shield back on. Viola!
214 of 248 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Josue from Jacksonville, NC
Parts Used:
W10124096
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Seven year old condenser fan was making noise when it was running.
The process to repair was very simple, I removed the back of the refrigerator to expose the motor area. I then removed three screws that held the condenser motor in place. once it was loose I detactched the electrical harness and removed the old motor. I then placed the new motor in place and secured it with the screws and reattached the new electrical harness that came with the new part. Once completed I reviewed it to make sure I didn't miss anything. I then replaced the cover over the motor area and enjoyed my success in repairing my own appliance with no added cost for labor, which would have been expensive I'm sure. The part purchased came with clear and consice instructions very easy to follow.
199 of 210 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
john from seaford, VA
Parts Used:
4388736
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set
Plastic bits dispensed from Ice Dispenser in Door
Removed Ice bin from Fridge

Removed all bolts on bin with nut driver...about six

Removed housing...be careful with spring on crusher/cube control rod

Removed C clamp on end of auger with small slotted screw driver and needle nose pliers.

Removed plastic nut on end of auger shaft

Removed Ice crusher jaws and laid them out in the correct order

Removed Ice propeller and installed new part

Put back together in opposite order

Easy
202 of 238 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tracy from Jacksonville, FL
Parts Used:
WP2180224
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
External Ice Guide Broke a Tooth and Fell Off
We waited two years to do this because we didn't want to hassle with a repair man to come out and charge us arm+leg for something so simple. Finally we searched and found the part on line. It came two days FASTER than promised. Kudos to Part Select.
Snapping it on was a breeze, although you do have to apply more pressure than feels comfortable with plastic clips. We can know get ice out of the external door system again.
170 of 186 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Cooper City, FL
Parts Used:
W10408179
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Ice maker would't fill with water
I first read your forum which was extremely helpful! I checked the continuity of the electromagnetic valve and got a 0 reading on the ice fill valve. The valve next to it which is for the water in the door had a 300ohm reading on my meter. This meant there was a broken wire somewhere in the coil which confirmed the valve was bad. I tried to get the part locally but was told it was on back order! Ordered it thru Part Select at the regular shipping rates and to my surprise it arrived the very next day!
The valve was the new style where you push in the tubing until it locks. I carefully trimmed each tube square with a sharp razor knife, the old valve used plastic compression fittings which had to be cut off.One of the inlet tubes was smaller than the opening on the valve. I then noticed that there was a reducer in the box that snapped into place making the line a perfect fit! Even though the inlet valve looked different than the original it was an easy installation. After replacing it, I had ice again! Totally impressed with the service and how quickly they shipped the parts on the same day! I will never again run around town trying to find parts! Thanks to all of the hard working employees at Part Select!
167 of 183 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from Winter Park, FL
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
154 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Conrad from Tucson, AZ
Parts Used:
8201537
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
The Water Dispensor Tubing Had Become Brittle And Broke .
Removed the face plate. Removed a few screws and unpluged a few electrical connectors and pulled apart. Removed the holding bracket and clear tubing from door. Cut new tubing at an angle to push through conduit. Reinstalled new bracket and re-installed electrical connectors. Snapped face trim on and bleed air out of system. . Water ran great.
207 of 344 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
T.w. from Batesville, AR
Parts Used:
WP2182179, WPW10329686
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Refrigerator Door quit closing on it's own......
Door quit closing on it's own......

** Order the following from www.partselect.com

Lower Door Closing Cam -- Part Number: PS323495

Upper Door Closing Cam -- Part Number: PS327641




1. 1/4 drive socket and standard socket
2. On top of door .... remove black plastic bracket cover on top of hinge
3. Have someone hold the frige door in place
4. On top of door .... remove 3 screws that hold the hinge onto the frige..... at this time, door will be loose
5. Lift door up and off the bottom hinge.
6. sit door on the ground. Tilt door at an angle for access to the "cam"
7. On frige, at the bottom, use socket to remove one screw that holds the old "bottom" cam in place..... then replace with new one.
8. While door is tilted, use socket to remove one screw that holds the "top" cam in place.
9. You will need to gently pull this cam out.... shouldn't take too much effort though.
10. Replace with new cam.
11. put door back on hinge
12. At top of frige, reinstall 3 screws
13. Reinstall plastic cover.
14. Voila, you're done

Thanks PartSelect !
140 of 153 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
helen j from murrells inlet, SC
Parts Used:
W10823377
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
where ic e dispencer spring is held to door broke at mold
after ordering ice dispencer repair kit, and removing the outer parts found out that the problem was the ice dispencer door shell . this part is no longer available.It seems to me that if whirlpool wants to have return customers they have to stand behind the product. Well I made a L bracket and drilled a hole to to recieve the spring keeper and glued this to the housing and used a 3 1/12"finishing nail as the pin all works fine
123 of 142 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jamie from Mitchell, SD
Parts Used:
WPW10190965
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Ice maker quit working
First I removed the three screws with a nut driver and then disconnected the wire plug from the old ice maker. I plugged in the new unit and re-installed the screws and instantly the unit started to work. I did have to adjust the water level on the unit ...just turn the small plastic knob (use a slotted screw driver) on the side of the unit counterclockwise to increase the water level (do not turn more than one full turn or you could damage the unit) . It works perfect and saved me lots of money!!
107 of 123 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Chesterfield, MO
Parts Used:
W10823377
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers, Socket set
Warm Air Getting Into Freezer
Patience is a virtue. The kit really works. 1st, lift the front plate of the ice dispencer by placing a flat head screw driver into the two slots at the bottom of the panel. When the panel is lifted up slightly at the bottom, push up on the panel to remove it. Careful not to break panel and the wires attached. Next, remove the wiring panel by removing the two screws on left and right sides. Then, unplug the old black ice cover from the wiring panel (this is the heating plug that you will nolonger need). Next, remove the parts and replace them with the parts in the kit, noting where each part comes from, etc. All parts in the kit are necessary and should be used. Some of the replacements need trial and error. Patience will be important. Also needed is a person that loves to solve problems, especially because the kit does not come with instructions. But the kit definitely works!
109 of 132 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Franksville, WI
Parts Used:
W10408179
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
water slowly leaking from fill tube- overflowing ice tray
unplugged fridge, turned off water supply, disconnected water supply line (towel to catch drainage). remove cardboard lower panel from back of fridge. remove 2 bolts holding existing water inlet valve assy to fridge. Disconnect 2 electric plugs from assy. water lines disconnect using push/pull method (mark where they go). If any water tube line has any surface imperfections trim off a small length of line using a razor knife (cut tubing perpendicular (or "square" )on the end. I had to remove small unused part from the new water inlet valve assy. Insert the 3 water lines to the correct spots: push them on,fully, give a tug to make sure they are connected fully. Reattach the 2 electrical plugs.Bolt the unit back in place. I connected the water & plugged it in, filled about 10 glasses of water and made sure an ice cycle ran, to check for leaks (none found). I cleaned off some of the dust on the back of the fridge, reattached the cardboard lower piece. and listened to the sweet sound of Ice filling, and not my wallet emptying to the service man!!
101 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 10657989700