Jonathan from Lilburn, GA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Sticking Light Switch
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
116 of 144 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Betty from Lake Village, IN
Parts Used:
WR9X442
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
thermostat control not working properly
repairman came looked it over said problem was thermostat control which was not made anymore and left charging service call $190.00 I went online found the control for $160.00 received it in 3 days put it in 30 mins later working fine.
29 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dilver from Milton, KY
Parts Used:
WR50X55, WR49X391
Difficulty Level:
Really Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers, Screw drivers
Refridgerator warm, freezer warming
refridgerater side warming, freezer warming
Appliance
General Electric Refrigerator

Model
TFXW20R

Level of Difficulty
Really easy

Time to do repair
1- 2 hours

Age of Appliance
More than 10 years

Tools
Pliers
Nutdriver
Screw drivers
Dilver From Milton, KY
Dec 05, 2011
0 out of 1 people found this instruction helpful



First I diagnosed the problem being a defrost timer as the symtoms are the same as the heater elements. I installed the timer and it worked great for about a week until the frost build up on the evaporator became too much again and then the symtoms returned. I then checked the heater elements and found that both were bad PLUS two clips to the elements were corroded. I then ordered the 2 heater elements. There is more than 1 heater element. Make sure you measure the length of each and then use the graph picture with "Parts Select" on the new ones before you order. There is about a 2" in length difference. Also one comes in a kit with thermostat and wires. Wrong for me. I really wanted that unit as I needed the harness for the bad terminals but it was the wrong heaters and it also came with a new thermostat. Luckly I did not order that one but did order a new thermostat to make sure I did not have to go through this ordeal again. When the parts came I had already replaced the terminals and was ready to go when FedX came. Just make sure you check your heaters before just buying the defrost timer as it may keep you from going back to redo your repair. Just doing your home work before ordering may save you much time in your repair. "PARTS SELECT" was one day on both orders and I just ordered standard shipping. They are great to do business with.
22 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jania from Novato, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Terry from Simi Valley, CA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clarence from Great Cacapon, WV
Parts Used:
WR60X177
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set
Wouldn't cool
I removed the 3 screws that held the motor and fan. Exchanged fan blades and reinstalled the fan and new motor

I was surprised to find the motor. The refrigerator/freezer was over 28 yrs old. Works fine now
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stephen from Jupiter, FL
Parts Used:
WR23X10725
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Existing light switch was hard to remove.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
14 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Carpinteria, CA
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Noisy Fan Motor - Bearing went out.
Moving the frig out and cleaning was the hardest part of this job - lots of dust collected over the 17 years the frig was in place. Once all the cleaning was done, with the frig out and back cover off (10 -12 screws taken off with nutdriver),I plugged the frig in and observed the the problem was a noisy fan motor. The motor is at the very back of the frig with easy access to the 3 brackets holding it in place.
Pull off the electrical clip. Remove the screw holding the bracket to the frame on the front bracket, leaving the bracket attacked to the fan. The other two screws remove from the fan, leaving the brackets in place.
Reverse the procedure when you receive the new part from PartSelect(great company to deal with)!
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mark from Somers Point, NJ
Parts Used:
WR23X10725
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Raymond from Los Lunas, NM
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set
Refridgerator was running constantly and condesor would get very hot, condesor fan would only turn on if I spun it.
Unplugged fridge removed the three screws that held fan on to fan frame unplugged condensor fan removed brackets from old fan and put them on new fan installed new fan plugged in fridge and now it works great!
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ronald from Matawan, NJ
Parts Used:
WR9X480
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers
Defrost clock failure
Contact points on original defrost clock burnt out after 36 years of continued use. Hotpoint does not stock replacement defrost clock. PartSelect replacement clock was a simple substitute which fits directly into the original mounting bracket. Space is tight to get the part out, so remove screw in upper right hand corner of bracket to disconnect clock from bracket. Then remove bracket and pull clock out. NOTE: Original part had wire color codes on the clock and the replacement part does not. Make a note of the order of the color connections and connect new clock in the same order. Replacement part has no ground wire since housing is entirely plastic. Push clock back behind frame. Reposition bracket. Install screw to mount bracket to clock. Then screw bracket back into frame. Glad I found Part Select online... saved me the hassle of getting my old spare fridge out of the basement!
9 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Cumberland, MD
Parts Used:
WR60X114
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
broken fan blade in the freezer compartment
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
7 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Daniel from Great Falls, VA
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers, Socket set
Not cooling - cond fan did not turn
Unplug refrig! Removed back cardboard covering (~5 screws)
(1) Cleaned all the dust out (hardest part!)
(2) Removed power wire to motor
(3) Removed 3 bolts holding motor to frame
(4) Removed motor/fan blade to the left
(5) Moveded fan blade to new motor (clean it!)
(6) Replaced motor, reinstalled 3 bolts
(7) Plugged power wire to new motor
(8) Tested it - worked fine, failed safe, drained to bilge!
Replaced back cover (had to tape it since I horked it up removing it)
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Frank from Philadelphia, PA
Parts Used:
WR60X177
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set, Wrench set
Started to see a little sweat in freezer and ice cream not getting hard frig staying on longer.
Pulled frig out. Removed back cover. Unplugged frig, unplugged motor. Removed fan from old motor first then 3 screws from bracket that holds motor and removed motor. Reattached motor back on bracket, reattached fan on motor. Plugged fan back in and then frig. Everything worked fine no more soupy ice cream !!
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from CONCORD, CA
Parts Used:
WR50X55
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Unit would not terminate defrost cycle resulting in melted frozen food
Turn of power to fridge. Removed all shelving in freezer section. Unscrewed back panel from freezer area. Removed old defrost term t-stat from top of evaporator coil assembly. Cut existing two wire leads, spliced in new T stat wires. sealed wire splices from water egress and clipped new t-stat in same position as old one. Reassembled rear panel, installed shelves. Turned power back on.That's it.
5 of 5 people found this instruction helpful.