This is an OEM replacement water filter for your refrigerator. The manufacturer suggests replacing this filter every 6 months or 300 gallons of water. If not replaced regularly, you will risk contamin...
In Stock
Order within the next 9 hrs and your part ships today!
The temperature sensor, also referred to as a thermistor, is used to monitor the refrigerator and freezer internal temperatures. The sensor is a small capsule like device that is protected by a white ...
In Stock
Order within the next 9 hrs and your part ships today!
This double inlet water valve has quick connections. This valve has 1/4 and 5/16 John Guest fittings for the outlet lines and a 1/4 compression fitting for the inlet line.
In Stock
Order within the next 9 hrs and your part ships today!
This is an OEM clear plastic module shelf insert (door shelf trim), which is the part of the door shelf bin that snaps onto the front to keep items contained securely on the shelf. This is the shelf i...
In Stock
Order within the next 9 hrs and your part ships today!
This dual heater kit replaces the single heater. It's redesigned to use two heating elements for a better defrost cycle.
In Stock
Order within the next 9 hrs and your part ships today!
The evaporator fan grommet is used to provide a cushion between the fan motor and the motor mounting bracket in your freezer. This genuine OEM part is about one inch in diameter and is red in color. I...
In Stock
Order within the next 9 hrs and your part ships today!
This is a genuine OEM replacement door flap for the ice maker in your refrigerator. This part goes by many different names, including door recess assembly, ice door assembly, dispenser door, ice chute...
In Stock
Order within the next 9 hrs and your part ships today!
The dispenser door solenoid is the part that controls the flapper door on your ice maker, allowing it to open and close when dispensing ice. If your ice maker is not dispensing ice or water, the door ...
In Stock
Order within the next 9 hrs and your part ships today!
Quick connector for plastic water line - 5/16" to 5/16"
In Stock
Order within the next 9 hrs and your part ships today!
This OEM compression ring is used to hold the evaporator fan motor in place. Signs that you may need to replace the compression ring are if the fan is noisy, or your fridge or freezer are too warm. We...
In Stock
Order within the next 9 hrs and your part ships today!
This tank stores water until the water actuator is activated and water is requested.
In Stock
Order within the next 9 hrs and your part ships today!
This is the replacement fruit and vegetable drawer for your refrigerator. It is made of white and clear plastic and is approximately 16 5/8" L x 15 5/8" W. The fruit and vegetable drawer slides in and...
In Stock
Order within the next 9 hrs and your part ships today!

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Problems and Symptoms for GSE23GGKJCCC

Viewing 25 of 25
Leaking
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Not dispensing water
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Fridge too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Freezer section too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Noisy
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Freezer not defrosting
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Ice maker not making ice
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Light not working
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Fridge too cold
Fixed by these parts
Fixing Fixing
How to fix it
Ice maker won’t dispense ice
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Frost buildup
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Door Sweating
Fixed by these parts
Fixing Fixing
How to fix it
Door won’t open or close
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Freezer too cold
Fixed by these parts
Fixing Fixing
How to fix it
Fridge and Freezer are too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Fridge runs too long
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Ice maker dispenses too little ice
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Clicking sound
Fixed by these parts
Fixing Fixing
How to fix it
Ice maker dispenses too much ice
Fixed by these parts
Fixing Fixing
How to fix it
Will Not Start
Fixed by these parts
Fixing
How to fix it
Doesn’t stop running
Fixed by these parts
Fixing
How to fix it
Too cold
Fixed by these parts
Fixing
How to fix it
Touchpad does not respond
Fixed by these parts
Fixing
How to fix it
Leaks water
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
ralph from bristow, VA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Socket set
Refrigertor water dispenser not working BUT ice machine is working
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo t he connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refreigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explantion. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call which can now be used to take the family to dinner after your "exhausting" 15 minute workout of removing about 10 screws and wheeling the unit in and out of place. Writing this article took longer! My 4 year old worked harder holding the flash light!
1021 of 1132 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from San Clemente, CA
Parts Used:
WR55X10025, WR02X10552
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fridge too warm, evaporator icing up
After replacing the defrost heater, main board and thermistor I still had the same problem. Called a repair guy and he (with the help of GE on the phone) diagnosed that the temperature sensor was bad. So I ordered from partselect and installed it and it fixed the problem. Been good for a couple months (knocking on wood). To install I had to cut the 2 wires to the old sensor, crimp the 2 new wires on and snap the new sensor to the clip on the evaporator. Very easy. Make sure you seal the ends of the wire crimps so moisture doesn't get in and corrode the connection.
600 of 719 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Stuart from Lynchburg, VA
Parts Used:
WR51X10101
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Defrost Heater blows out, refrigerator frosts up, then stops cooling
Disclaimer - if you aren't confident about doing this repair, call a repair specialist in. Also, take care not to damage the freezer coils as they have refrigerant in them that I'm told is harmful if it leaks. It may also be under pressure. The instructions that follow won't require you to touch the coils. There is no need to unplug the r efrigerator or disconnect the water supply to do this repair. The screw driver you will need is a phillips (the one withe the + head).

1st, take out your frozen food (which, if you need to do this repair may not be frozen) and put it in a cooler or the refrigerator.
2nd, remove the ice cube bucket and dump the ice cubes in the cooler to help keep the frozen food cool. Turn the ice cube maker off.
3rd, remove the freezer shelves.
4th, locate the panel covering the freezer coils. It's a panel at the back of the freezer. It hides the freezer coils and protects them from damage. It's held in place by two screws located at the top left and right corners of the panel.
5th, unscrew the screws holding the panel to the refrigerator.
6th, detach the clip at the top of the panel.
7th, remove the panel. You should see the coils now. The coils will be covered in frost if the defroster heater has failed. If the coils are not covered in frost, there may be another reason for the refrigerator failing to cool.
8th, even if the coils are covered in frost, you should also inspect the defroster heater at the bottom, underneath the coils. The business end of it is a long tube running horizontally between two wires. If it's black like a badly burned out light bulb, then it's failed. If the bulb appears fine, you may have a different reason for your refrigerator and freezer frosting up. We'll assume that the defroster heater has blown out, and proceed.
9th, place a towel at the bottom of the panel space, to soak up any water that melts and runs down. There is a drain under the coils. It collects water that melts during the defrost cycle, but I'd rather mop up the water instead of relying on the drain.
10th, use hot air blowing from the hair dryer to defrost the coils. Just play the air from the hair dryer over the coils, starting at the top, and working down. The frost will quickly melt and the water will be soaked up by the towels. If you want things to go faster, you can throw hot water on the coils to melt them faster, but that produces more water to mop up, and makes a big mess. It's also dangerous to have water lying around if you then decide to use the hair dryer to continue defrosting the coils.
11th. MOST IMPORTANT. Don't use your screwdriver or any other sharp object to pick away at the frost on the coils. If you damage the coils the refrigerant could leak out. I'm told that it's dangerous stuff. Furthermore, I expect that you'd have to buy a new refrigerator if you damaged the coils.
12th, once you've defrosted the coils, locate the defroster heater and bracket assembly again. It's held in place by two screws, and has two insulated wires running into it on either side. Unscrew the screws, disconnect the wires and remove the assembly. Throw it away - there are no useful parts in it.
13th, install the new defroster heater and bracket assembly by connecting the wires to it, mounting it back into its place, and rescrewing the screws.
14th, put the panel back in place, replace the clip, and screw the panel back in place.
15th, turn the ice cube maker back on and replace the ice cube bucket and shelves. Put your food back into the freezer.
16th, use the freezer and refrigerator as normal. If the defroster heater fails again (I'm on my third one in less than six years), you'll notice frost building up on the panel at the back of the freezer before your freezer and refrigerator stops cooling. The frost build up is your signal to defrost the freezer and buy another defroster heater and bracket assembly. I don't know why this part is so weak, and don't know any fix except to keep replacing it.
407 of 432 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!