Models > GTH22SHPARBS > Instructions

GTH22SHPARBS General Electric Refrigerator - Instructions

Jump to:

All Instructions for the GTH22SHPARBS
1 - 15 of 702
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
ralph from bristow, VA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers, Socket set
Refrigertor water dispenser not working BUT ice machine is working
The very first symptom here is important! The door water dispenser is not working but the ice macine is working. You may only have a frozen water tube in the door so do the following before diagnosing that your solenoid valve is bad: 1) the tube usually runs under the front of the refrigerator and usually has a quick disconnect. Undo the connection and press the dispenser. If water comes out of the tube you have a frozen or blocked tube in the door. 2) Immediately adjust the temperature in the freezer and warm the freezer compartment as much as you can without destroying the freezer contents. Wait 24 hours. This will usually unfreeze the line. Do not waste your time with a hair dryer. NOW, if this doesn't work and you are convinced you need to order and replace the solenoid, follow these steps. Assemble your tools first. I needed a good ratchet set and a screwdriver. A shop towel is helpful for spilled water. A light is handy. Pull out the refreigerator to gain access to the rear of the unit. Unplug the power and close the water valve (older homes, you may need to actually shut the house water supply). Remove the screws which hold the cover over the lower half of the refrigerator. On the left you will see the solenoid. It's always good to see that your new part matches the one you feel needs replaced. They may not match perfectly due to changing design but they should be very similar. One screw holds this part in place and access is very simple. Now simply unplug the electrical connections. In my case, one blue "blade" type connection (powering the water) and one red "blade" type connection powering the ice maker. They are not the same size and this coupled with the coloring means you will not accidently switch them. pull the tubes clear of the solenoid. This is simple and needs no explantion. Grab your new solenoid and reattach both the electrical and water lines (two, remember, ice maker and drink dispencer). Replace the single screw. Re-attach the rear, lower refrigerator cover and go to the front of the unit to check the water. You can listen carefully and hear the power engage from the new part bringing you water. Clean up, replace the refrigerator back to its place and look really tired when your wife sees that you worked "so hard"! You probably saved at least $50-$80 from a service call which can now be used to take the family to dinner after your "exhausting" 15 minute workout of removing about 10 screws and wheeling the unit in and out of place. Writing this article took longer! My 4 year old worked harder holding the flash light!
1022 of 1133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Holly Springs, NC
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
The refrigerator made continous "whooing" sounds that increased and decreased in pitch. Sounded like a ghost. Would keep us up at night. Also noticed that the heater was not heating under the evaporator coils.
After checking the stories, the consensus of opinion was to change the mother board. I had a tremendous help from Tom Paone at quality@applianceeducator.com. He also told me to change the motherboard but to make sure that the coils were totally defrosted before starting up the refrigerator after changing the board.

Took off three nuts around the board at the back of the unit. Removed the input wires and you have to push in the plastic tabs holding the board in. Then just put the new board in place and push till the tabs click. Re-install the wires and put the cover back on.

Really simple task,

It is now a week since doing this and the unit is working perfectly. No soulds and good nights sleep. The ghost has moved on.
556 of 645 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Mike from Scottsdale, AZ
Parts Used:
WR50X10068, WR55X10025
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Freezer wouldn't maintain temperature ... got warm.
The freezer in my side-by-side kept warming up -- often 20 degrees or more, which of course caused the fresh food side to warm up also. I do a lot of jump-in-with-both-feet home repairs, but never on a large appliance. Not having an ohmmeter, which cost about $100 for a reliable one, I took the symptoms to the internet. Countless self-help sites and U-Tube videos later, I was positive it was one of two possible problems, either the defrost thermostat was broken and the defroster wasn't coming out of its cycle or the temperature sensor wasn't reading the correct temp and thus kicking in the fan motor when needed. Fortunately I found both parts easily on PartSelect.com and the total cost for both, including shipping, was $30, less than 1/3 of the cost of an ohmmeter. Not knowing for sure which part it was that was bad, I ordered both, figuring, since I had to pull out the panel anyway, I might just as well replace them both ... the price was right. (In retrospect I should have order 4 Temperature Sensors as my fridge has two in both the freezer side and the Fresh Food side. Any one of them being bad could have caused the same problem. Fortunately, I was lucky because it was either ONLY the Defrost Thermostat or I just happened to pick the right Sensor, but the repair worked.)

The repair was easy: Unplug the power. A Nut Driver removed the four screws holding on the panel in the back of the freezer. A screw driver removes the one screw holding the lamp cover in place. Remove the light bulbs, pull off the panel and right above the freezer coils you'll see both parts -- plain as day. (If your coils are clogged with ice, you will probably need de-ice first.) Cut the wires to both parts as close to the parts as you can to leave as much wire exposed as possible. Strip the ends of all four wires about 1/2 inch and also on the new parts. Match up the wires in the fridge to the wires on the parts and twist the ends together (Note: both wires on the Sensor are white so they match up either way, but the two wire on the thermostat will need to match up orange to orange and pink to pink.) I used silicone filled wire nuts, which you can buy at any hardware store or use your own wing nuts and fill them with silicone or shoe goo which works just as well ... anything to keep the moisture out and prevent the wires ends from corroding. Tuck the wires up and replace the panel, light bulbs and light cover That's it. Very easy. By far the hardest part was wedging my wide body into the narrow freezer compartment. Some one-handed work added a little extra time to the project.

In my case the freezer fan didn't kick in for about twenty minutes after I plugged it back in, but I assume that it either begins in the defrost mode or it takes that long for it to reset itself ... either way the repair worked great.
295 of 348 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michele from North Smithfield, RI
Parts Used:
WR55X10025
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers
my refigerator was warm but the freezer was cold and working correcttly
I went to a GE repair center to explain my problem, the service center reccomended that I have a techinician come out o look at it. $75.00 for the visit and what ever labor and materials wuld cost.

I went on line to see if there were others having this same problem and found that there were many with the same problem.

After reading some of the ways that people found out what was wrong ...it became a matter of three components, the timer, heater or thermostat.

I tried the most common component and the less expensive one first , the thermostat switch I installed it very easily snipping two wires and attaching the news using wire nuts I used the diagram on this website to pinpoint the component and there has not been a problem since.
269 of 338 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
michael from pennsburg, PA
Parts Used:
WR57X33326
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Wrench set
Water dispenser not operating
Model includes filtered ice maker and water dispenser from front of unit. Water maker just suddenly stopped working but ice maker continued to work fine. After some phone calls to trouble shoot at a high level, I figured it was worth a try to buy the replacement part of the most likely culprit and see if it did the trick. Would have cost maybe $150 or more for service tech to make house call, provide the part and do the switch. Buying the part was only $40 and replacement was easy. Remove access panel from behind fridge and identify valve. It has intake water from the filter then has two outbound lines. One to ice maker, one to water dispenser. All function is in one part, but each outbound line has its own functioning valve. Unplug fridge, turn off water supply, disconnect all connections from old valve and reattach to new valve. When re-hooked, be patient in allowing water to re-fill line before coming out of dispenser in front. Likely to doubt it works, but surprised how long it took for water to fill line resevoir.
192 of 228 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gary from El Cajon, CA
Parts Used:
WR57X33326
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set, Wrench (Adjustable)
Leaky water valve
Unplugged the refrigerator, turned off the water supply, and then removed the back cover/access plate. Observed and made wiring notes to ensure I install the part correctly. Unscrewed the bracket holding the water valve assembly, and lifted it up to see and remove the three water lines (one input, two output). The input or supply line is a compression fitting...just use an adjustable wrench to loosen the nut and lift off the line. Then remove the two output lines by depressing or pushing in on the white plastic rings that surround those two holes ...the lines just slide out, but you have to push in on those rings. Remove the two electrical connectors...just wiggle them off One connector was very stubborn but it eventually came off. Try to be gentle, and pull on the connector heads...not on the electrical wires.
Assemble the lines and electrical connectors on to the new part. The two output water lines just slide in...you dont need to push in on the rings. You'l feel them seat into the valve. Don't worry.
Put it all back the way you found it, turn on the water supply, and plug in the power cord. Check for leaks. I had no leaks and was very pleased. This is so easy a chimp can do it, but let everyone think otherwise! No biggie.
161 of 181 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alejandro from New York, NY
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Refrigerator wouldn't cool, constant clicking noise
Unplug refrigerator. First I removed 3 screws to remove cover for Board ASM Main located on back of refrigerator then loosen Board by pressing on each of 4 plastic pins then unscrew ground wire (green) then transfer all plugs from old Board to new Board, put back new board through pins, screw back ground wire then put back cover then plug back refrigerator, took 5 minutes
148 of 176 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Larry from Menomonie, WI
Parts Used:
WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
refrigerator was getting too cold
I removed the old temperature sensor by cutting the wires. I attached the wires of the new sensor with wire nuts and mounted it in the same bracket.
142 of 197 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jonathan from Lilburn, GA
Parts Used:
WR23X10725
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Sticking Light Switch
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
116 of 144 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
anthony from burke, VA
Parts Used:
WR50X10068, WR55X10025
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Nutdriver, Pliers
freezer defrost and then after some time would work.
one repair man said I needed freon. sears repair man said my evaporators leaked. and should buy a new fridge. I installed the parts for less than $30.
dried the freezer compartment removed back panel and asst parts. removed screws from evaporator assy and replaced def therm. soldered leads/wing nuts. removed cover from sensor temp and again connected leads. working fine.
92 of 96 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Otisco, IN
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Repeatedly stick in defrost, raising temps in fridge and freezer for hours at a time, some times for days. Repair tech was called out twice to look into this problem, but the temps returned to normal both times before he arrived, therefore, he never could diagnose the problem with a certainity as wh
The main board is easy to get to behind the access plate. You will find seven different wire harness plugs, six which are white, that are impossible to remove without breaking the retaining clips which hold them in place....but that's OK.....you are throwing away the old board anyway, so nothing lost. The plugs will snap back into each of their respective terminal locations without a problem. Be sure to treat the four white, plastic pins that hold the board in place delicately....you will not want to mess those little dudes up!
96 of 121 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ken from Gibson City, IL
Parts Used:
WR55X10942
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Pliers
Ice dispenser quit working and kept making a clicking sound
All you have to do is replace the circuit board which is really easy. Still kinda mad because the fridge is less than 2 years old. If you hear the clicking noise its coming from the circuit board.
86 of 97 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Suwanee, GA
Parts Used:
WR60X10209
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Warm freezer and no ice
This story starts with a GE side-by-side refrigerator that has always had wide temperature swings and a temperamental water dispenser. The ice maker was not making ice, and the built in digital thermometer showed it was running warm. I suspected that the heat exchanger was full of dust and so looked there. What I found was that the condenser tank was hot to the touch and the fan wasn’t running. As an experiment, I aimed a fan at the it for a while I saw that the freezer temperature dropped back to normal.
.The fan is marked as 11.2 DC so I checked for voltage at the fan and found some. With three wires and no wiring diagram I wasn’t sure this answered all the questions, but hooking the fan to a 12 volt power supply didn’t get it to spin.
I priced parts at a couple websites before using partselect.com . They also have a good diagram to look at (Sears diagrams are really poor). I ordered the part with 2-day shipping; it arrived on time, was correct and fixed the problem.
94 of 124 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DAVID R. from BATH, NY
Parts Used:
WR55X10942
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver
Refrigerator stopped freezing and cooling frige
Well, I first had a local service guy look at the frige. only to find out his opinion was to replace the entire unit, because the Mother board cost more than the unit was worth. Me not accepting that answer, decided to look on line for a part and availability as well as price. Surprise, Part Select had what I wanted. Now, on the back of the unit in the upper left hand corner is the access door for the mother board.Find it, but before proceeding disconnect the power supply from the wall receptacle. Remove the surrounding screws on the access door with a nut driver and the correct size METRIC socket. Disconnect the wiring connectors on both sides of the board. Now there are 4 plastic type (mine were white) retaining studs holding the board in place. BE CAREFUL not to break these as you gently pull the board off studs. Replace board with new one, and restore wire connectors in their perspective places. Each connector has a different amount of pins inside so connecting them is easy. I know nothing about refrigeration, and this was a piece of cake. Less than 15 min. Unit cools like never before!!!
77 of 85 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Gerald from Benicia, CA
Parts Used:
WR30X10093
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
89 of 122 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GTH22SHPARBS
1 - 15 of 702