Models > TAX3DNXARWH

TAX3DNXARWH General Electric Refrigerator

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for TAX3DNXARWH

Viewing 1 of 1
Keep searches simple, eg. "belt" or "pump".
$29.54
In Stock
Order within the next 12 hrs and your part ships today!
No Longer Available
$62.27
The filter dryer filters refrigerant that travels through the sealed system of the refrigerator.
In Stock
Order within the next 12 hrs and your part ships today!
Special Order
Special Order
Special Order
$6.80
Special Order
$7.60
Special Order
$14.04
Special Order
No Longer Available
No Longer Available
$6.80
Special Order

Questions and Answers

Be the first to ask our experts a question about this part!

Common Problems and Symptoms for TAX3DNXARWH

Viewing 1 of 1
Will Not Start
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Alastair from Troy, VA
Parts Used:
WR2X8289, WR2X2195, WR12X937
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Faded white plastic
I had to remove the inner door panel to gain access to the door handle fastening screws. There was a non-removable foam-insulation barrier blocking access, so I had to align screwdriver just right, then push the screwdriver head through the hard foam to reach the screws.
I got the job done.
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from Menasha, WI
Parts Used:
WR9X498
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Unit runs,but freezes up, cold controll stuck on.
UNPLUG UNIT;open door, pull straight off,the control knob. Under freezer tray, release white plastic holder containing capillary tube (take note how it fits). Straighten tube. On back of unit; remove 3 screws holding condenser grid. GENTLY pull outward and down the grid just enough to access the 2 screws to the cover. Remove cover. Pull t he capillary tube out of unit (white plastic cover on it). Write down where the wires go, unplug them. Remove the two screws holding the control to the unit. Reverse procedure. Take note to center the control, so knob will fit. Install wires. Install cover. Remove white plastic cover on old capillary tube, install it on new part. Gently push tube thru back of unit. Gently fold tube on end and fit into white plastic holder. fit holder under freezer tray. Gently return condenser grid back into place, install the 3 screws. Set control knob to about half way. Plug unit in. use thermometer to set final temperature.
Was this instruction helpful to you?