- James from Centerville, OH
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Socket set, Wrench (Adjustable)
Leaking water valve
Removed black cardboard covering on back of refrig with nut driver (6 screws), turned off water supply to pump, removed cooper waterline to pump with adjustable wrench, removed 1 screw holding pump to refrigerator, removed plastic waterline from pump by turning hose counter clockwise. Inserter plastic water line in new pump by screwing line in clockwise, pushed orange plastic stop around waterline into pump, connected cooper water line to pump first wrapping threads on pump with teflon plumbers tape, reinstalled pump to refrig and cardboard back on refrig with 6 screws.
One side note:.
This is the second pump which has burst at the blue plastic seam in seven years.
One side note:.
This is the second pump which has burst at the blue plastic seam in seven years.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jonathan from Lilburn, GA
- Parts Used:
- WR23X37285
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Sticking Light Switch
I applied some tips learned by reading other reviews. So before I started I grabbed my trusty vise grip pliers and a small screw driver. I locked onto the switch actuator, the part that the refrigerator door pushes in, with the vise grips and pulled on it just hard enough to get the screw driver inserted in the right side to push in the catch clip so the switch could be pulled out further each time the catch clip was depressed to the next detent. Then I used the screw driver on the left site to encourage the switch past the detents on the left and very quickly the switch was out of the mount. The wires from the refrigerator pulled out with the old switch. I unplugged the old switch from the wires and plugged in the new switch and shoved the new switch back into the mount, wiggled it a couple of times to make sure it was secure and the job was done. Once I applied the vise gripes at first, the whole job took less than a minute.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Alan from Houston, TX
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver, Pliers, Screw drivers
Water dispenser did not work (ice-maker did work)
This is a side-by-side frige with water and ice dispenser in the left freezer door. I first checked for possible water line freezing in the freezer door or in the water chiller area (behind the vegetable drawers) as described in e-articles I had read, but this did not appear to be the problem. I found two solenoid valve pairs; one that routes dispenser or ice-maker water to the filter and the other that routes the water to the end device. I ran a couple of tests on the solenoid valves and found that the first inlet valve that sends water to the filter did not work, but the second valve that relays the water to the dispenser was still working. By temorarily connecting the wiring for the dispenser solenoid to the functioning ice-maker solenoid, I confirmed that the wiring and switch were working properly and that the problem must be the solenoid itself (it also still hummed when the dispenser button was pressed). The entire quad solenoid valve assembly can be pulled out after removing the one hex-screw on the back of the frige (the assembly is all held together with a bracket). I disconnected the wiring connector to the solenoid valves. I disconnected the plastic water tubing by pushing it toward the fitting and then depressing the tubing inlet ring to release the tubing. I removed the two screws holding the solenoid valve and replaced it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Gerald from Benicia, CA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
ice stalactites were drooling out of the icemaker and gumming up the cubes in the receiving tray.
I first shut off water flow to the fridge. Examination of the package (which was not exact in appearance to the original) demonstrated that the electrical connectors were well-insulated so I arrogantly and successfully proceded without disconnecting the power. My fridge is old enough that the model doesn't appear exactly on anyone's list so I wasn't alarmed that it took an extra 10 minutes or so to noodle out how to adapt the slightly different inlet cowling and electrical cord with extension, but the device is pretty simple.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Soon I loosened the two mounting screws with a nut driver, used a screwdriver to pry away the plastic snap-in housing over the electrical socket on the fridge inner wall and pulled away the electrical plug. The original water fill tube remained in its cavity, ready for re-use.
The new unit's mounting points matched the original screw locations perfectly, as did the fill cowling - which on the replacement icemaker has two possible attachment points. The new unit's electrical connector required an extension pigtail to adapt to my socket, but it was included in the package. The extra cable posed a minor cosmetic issue because it hangs in the collection basket a bit, but that will soon be remedied with a tie wrap.
After the water was restored and an anxious wait of a few hours, we had well-formed ice cubes that weren't all stuck together and the stalactites haven't reappeared.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Dan from West Bloomfield, MI
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver
Ice maker stopped working
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.
The icemaker started making ice very soon after turning the unit on.
The icemaker started making ice very soon after turning the unit on.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Laura Beth from Mandeville, LA
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
broken ice maker part
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
Simple
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Antioch, CA
- Parts Used:
- WR17X4312
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
The oiginal Ice Bucket auger became rusty and discoloered the ice.
I went on line to find the part. Luckily I found PartSelect.com. All I had to do was enter the model number into the search box and scroll through the list of parts.
I ordered the part over the weekend and recieved it on Tuesday!
All I had to do was remove 4 screws from the original Ice Bucket and attach the new one.
Perfect fit in under 15 minutes!
Awesome place to do business with! I hope I never have to do another repair, but if I do I will go to PartSelect first!
I ordered the part over the weekend and recieved it on Tuesday!
All I had to do was remove 4 screws from the original Ice Bucket and attach the new one.
Perfect fit in under 15 minutes!
Awesome place to do business with! I hope I never have to do another repair, but if I do I will go to PartSelect first!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eddie from Freeport, NY
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from Greenville, NC
- Parts Used:
- WR62X23154
- Difficulty Level:
- Difficult
- Total Repair Time:
- More than 2 hours
- Tools:
- Nutdriver, Screw drivers
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JAMES from LEDGEWOOD, NJ
- Parts Used:
- WR57X10023
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
water leak on the water valve
I had noticed water on the front left of the fridge on the floor.I thought it was the drain in the freezer so i poured hot water with baking soda into the drain but it didn't help..I pulled the fridge out and saw water dripping from the water valve solenoid.I searched the web for parts and found Parts select.com.I found the part quickly and they had pictures from all angles to assure me that it was the exact part which was great.The transaction on line was simple and the part came the next day.I will definitly use this sight again
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Jeffrey from Bluefield, WV
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Nutdriver
Ice maker quit making ice
the first thing i did was replace the water valve at the bottom of the refrigerator but that didn't work so then i spent more time researching the problem on your site and your diagnostic said to replace the ice maker so i ordered it, took the old one out, plugged the new one in and we had ice the next day.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- FERNANDO from MIAMI, FL
- Parts Used:
- WR51X10055
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joel from Flagstaff, AZ
- Parts Used:
- ADAPTER
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
Older Side By Side GE refrigerator needed filter replaced
Because of the age of the refrigerator, I was unable to find original water filter replacements. I found an adaptor through PartSelect, ordered and received it within 3 days. I was then able to find a replacement filter to work for my appliance. It was easy to install. The Adaptor snapped into the port where the old filter went and the new filter screwed into the adaptor...Water / Ice system is working like new again.
Thanx
Joel
Thanx
Joel
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Joe from Brentwood, TN
- Parts Used:
- WR30X10093
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Quit making ice.
There were not two screws as the instructions said. There was only one screw and I had to firmly pull it out after taking out the one screw. Then, to put the new one in, I had to line up two slots on two knob-like things and push it in firmly. Then screw the one screw in.
Other than the two-screw problem, it was easy.
Other than the two-screw problem, it was easy.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Paul from Danvers, MA
- Parts Used:
- WR57X10023
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers, Wrench (Adjustable)
Leaking Water
Unplugged frig. Turned off water supply to pump. Removed black cardboard covering on back of frig with nut driver (6 screws).
Took digital photo of assembly to confirm reassembly position.
Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.
Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.
Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.
NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.
Took digital photo of assembly to confirm reassembly position.
Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.
Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.
Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.
NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.
Was this instruction helpful to you?