D KIRKE from CORVALLIS, OR
Parts Used:
5309918806
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Erratic light.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Allen, TX
Parts Used:
5304469403
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
The ice maker quit making ice.
I noticed that the two gears weren't meshing together so upon inspection I saw that one of the gears had an inner piece missing making it weak so it kept popping out away from the other great. I ordered the new gear and unscrewed the old one off and put the new one on. So easy. It made Ice beautiful after that
Was this instruction helpful to you?
Thank you for voting!