Models
>
ACG150NLD1
ACG150NLD1 Frigidaire Refrigerator
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for ACG150NLD1
Viewing 3 of 3Keep searches simple, eg. "belt" or "pump".
$27.45
This 40-watt light bulb has a standard screw-in base and is used in many different appliances. If your current bulb is burnt out or broken you will need to replace it. This light bulb is a genuine OEM...
In Stock
Order now and your part arrives by Jul 23
In Stock
Order now and your part arrives by Jul 23
This is the door shelf end cap for your refrigerator. It connects to the refrigerator door and keeps the door bar in place. Your refrigerator will have two shelf end caps, one for the right side and o...
No Longer Available
This white end cap is a little over two inches long. It is used for the right side of either the refrigerator of the freezer door shelf.
No Longer Available
This is the door shelf end cap for your refrigerator. It connects to the refrigerator door and keeps the door bar in place. Your refrigerator will have two shelf end caps, one for the right side and o...
In Stock
Order now and your part arrives by Jul 23
$31.85
The light socket on your refrigerator houses the light bulb and connects it to the power source. If you notice that your refrigerator light does not come on when you open the door, you may need to rep...
In Stock
Order now and your part arrives by Jul 23
$57.53
This white gasket is used to seal the refrigerator door when closed to keep the cool air inside and the room air out.
In Stock
Order now and your part arrives by Jul 23
In Stock
Order now and your part arrives by Jul 23
In Stock
Order now and your part arrives by Jul 23
This white door gasket is used to make an air-tight seal for the cabinet when the door is closed.
No Longer Available
This bar can be cut to fit your refrigerator if necessary.
No Longer Available
Common Problems and Symptoms for ACG150NLD1
Viewing 5 of 5Light not working
Fixed by these parts
How to fix it
Door Sweating
Fixed by these parts
How to fix it
Fridge too warm
Fixed by these parts
How to fix it
Leaking
Fixed by these parts
How to fix it
Fridge runs too long
Fixed by these parts
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- William from Alexandria, VA
- Parts Used:
- 218906802
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Light socket melted around bulb
After unsuccessfully trying to change the blown light bulb I discovered that the plastic light socket had gotten so hot that it melted and permanently fused with the blown bulb. After my new socket arrived in the mail I just popped the temp control assembly out with a screw driver and removed the old socket and placed the new one in.
... Read more
Whole operation to 5 minutes.
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Emily from Saint Louis, MO
- Parts Used:
- 5308007123, 218730603
- Difficulty Level:
- A Bit Difficult
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Gasket was old and not sealing correctly
There are quite a few bolts that needed to be loosened to remove the old gasket and put on the new one. We tried to do it by just loosening and leaving the door on the fridge...take my advice. Just remove the door, remove all the bolts, put the new gasket on and replace the bolts then the door. MUCH EASIER than trying to fit it on inch
... Read more
by inch and having it pull back out etc.
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- FREDDIE from WHITAKERS, NC
- Parts Used:
- 5303276514, 5303007173
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers, Screw drivers
Freezer stopped freezing food.
I unplugged electrical cord to the freezer. I removed the cover to the relay and load protector. I labeled the wires and made a diagram on the proper placement of each wire going to the relay. I unplugged each wire and removed the relay. Then I removed the load protector. I installed the new load protector and new relay. I placed the wire
... Read more
s on the proper terminals of the relay. I replaced the electrical cover to the relay and load protector. I plugged the electrical cord back in the electrical outlet. My freezer started working again. I placed several bottles of water in the freezer to make sure the freezer was working properly before I restocked it with food.
Thanks again for the help. You just saved me about $400.
Thanks again for the help. You just saved me about $400.