Models > GSIW36CH1

GSIW36CH1 Frigidaire Refrigerator

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for GSIW36CH1

Viewing 9 of 9
Keep searches simple, eg. "belt" or "pump".
This 120 volt, 60 hertz defrost timer is used to switch the refrigerator into a 30 minute defrost cycle after eight hours of compressor run time. The cycle allows the heater to clear frost from the ev...
In Stock
Order now and your part arrives by Nov 21
During automatic defrosting, this refrigerator thermostat permits heater operation while the evaporator coils are cold, then breaks the circuit at the cutoff temperature to help prevent overheating. I...
In Stock
Order now and your part arrives by Nov 21
This white door shelf end cap is used for right side of some refrigerator door shelves.
Special Order
To drive the fan that circulates cold air through the refrigerator and freezer compartments, this evaporator fan motor uses a center hub mount and rotates clockwise. The shaft measures 1/8 inch in dia...
In Stock
Order now and your part arrives by Nov 21
This white door shelf end cap is used for left side of some refrigerator door shelves.
In Stock
Order now and your part arrives by Nov 21
Interior lighting depends on a secure connection between the bulb and its power supply. This refrigerator light socket holds the bulb in place and provides the electrical contacts needed to illuminate...
In Stock
Order now and your part arrives by Nov 21
This evaporator fan blade is used to move cooled air through the refrigerator or freezer compartments when driven by the fan motor. A cracked, warped, or loose blade may vibrate, strike nearby parts, ...
In Stock
Order now and your part arrives by Nov 21
Sold individually.
In Stock
Order now and your part arrives by Nov 21
This white hinge pin bearing pivots the freezer and refrigerator door.
No Longer Available
Sold individually.
No Longer Available
Sold individually.
No Longer Available
This filter drier is used to remove moisture and trap small particles in the refrigerator sealed refrigerant circuit. It helps keep dirt, metal fragments, and moisture from moving through the cooling ...
In Stock
Order now and your part arrives by Nov 21

Common Problems and Symptoms for GSIW36CH1

Viewing 13 of 13
Fridge too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Freezer not defrosting
Fixed by these parts
Fixing Fixing
How to fix it
Noisy
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Freezer section too warm
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Light not working
Fixed by these parts
Fixing Fixing
How to fix it
Leaking
Fixed by these parts
Fixing Fixing Fixing
How to fix it
Will Not Start
Fixed by these parts
Fixing Fixing
How to fix it
Fridge runs too long
Fixed by these parts
Fixing Fixing
How to fix it
Fridge and Freezer are too warm
Fixed by these parts
Fixing Fixing
How to fix it
Freezer too cold
Fixed by these parts
Fixing Fixing
How to fix it
Fridge too cold
Fixed by these parts
Fixing Fixing
How to fix it
Frost buildup
Fixed by these parts
Fixing Fixing
How to fix it
Too warm
Fixed by these parts
Fixing Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Stephen from Warrington, PA
Parts Used:
5303917954, 215846602
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers
Fridge got warm and freezer coils were frosted
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.

Pulled plug.

Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be re moved.

Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.

Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.

Removed old badly corroded thermostat.

I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.

Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.

Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.

Plugged back in and everying is working great!
340 of 407 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jordan from Maumee, OH
Parts Used:
5308000010, 5300158289
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Tools:
Nutdriver
Noisy fan
1. Removed the 7 nuts using the nut driver from the freezer back panel inside the freezer.
2. Remove the back panel. The evaporator motor and fan are located above the coils.
3. Unplug the wiring harness.
4. Remove the two gold mounting screws holding the motor and fan in place.
5. Remove the motor and fan including th e brackets.
6. Install the new motor and fan onto the mounting bracket.
6a. Attach the green ground to the mounting bracket.
7. Screw the two gold screws back into the freezer.
8. Attach the new wiring harness. Note, the old harness had a mounting hole/space for it to connect to the wiring harness of the freezer. The new motor's harness was not long enough for this, so it is connected freely to the freezer harness.
9. Use the hair dryer to melt any ice that may have formed on the coils and hole where the fan goes.
10. Turn the freezer on to see if the fan turns on.
11. Reinstall the back panel.
All done!
153 of 180 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tad from Lancaster, OH
Parts Used:
215846602
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Side-by-side .. freezer working, fridge not cooling
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc . After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself
48 of 52 people found this instruction helpful.
Was this instruction helpful to you?