Models > A4TXCGFBW00 > Instructions

A4TXCGFBW00 Amana Refrigerator - Instructions

Jump to:

All Instructions for the A4TXCGFBW00
1 - 15 of 229
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
garth from forest lake, MN
Parts Used:
WPW10662129
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
My refrigerator stopped cooling and the freezer section stopped freezing
I knew the chances of all the freon leaking out was unlikely so I looked at the wiring to the compressor and there was a capacitor and a starter/overload so i figured I would start there. I went on line and found the parts at this site and they were less than the minimum service call charge for a service tech so I figured what the heck let's give her a shot so I did give it a shot. I ordered the parts and they were there in less time than a service tech could come out and i installed the parts and guess what for 90.00 in parts and 15 minutes in time I repaired my refrigerator. Thanks guys, It took less time to order the parts than it did to make the repair so thanks, your website rocks and is very well designed so my hat is off to you guys!
394 of 474 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Cathy from Winter Park, FL
Parts Used:
WPW10225581
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
Fridge was getting too warm, ice buildup on coils.
WARNING: REPLACING THIS PART REQUIRES CUTTING AND SPLICING ELECTRICAL WIRES. RISK OF ELECTRICAL SHOCK OR FIRE. DO NOT ATTEMPT THIS REPAIR IF YOU ARE NOT EXPERIENCED WITH ELECTRICAL WIRING.

Part Info:
The bi-metal strip is clipped onto the evaporator coils and is designed to regulate the defrost coil temperature. If it is not functioning properly you may notice ice buildup preventing air flow (and preventing proper refrigeration), or more rarely the freezer side may get too warm during the defrost cycle.

Materials:
* Replacement bi-metal strip
* Wire cutters
* Wire strippers
* Wire nuts
* Electrical tape
* 10MM socket

Steps:

1: UNPLUG THE FRIDGE! If there is ice buildup, wait until the ice has melted. A box fan blowing at the ice will help melt it more quickly.

2: Remove the panel covering the evaporator coils. It's located inside the fridge, on the freezer side.

3: Un-clip the bi-metal strip from the evaporator coils.

4: Unplug the wires from the evaporator fan, defrost coil and bi-metal strip, then disconnect the main connector that is plugged into the rear wall.

5: Clip both wires to the old ( bad ) bi-metal strip. Cut close to the casing of the bi-metal strip so there are long wires to splice onto.

6: Strip 1/4 to 1/2 inches of insulation off of the ends of the wires ( depending on the size of the wire-nuts you use). Twist the bare wires slightly to prevent fraying.

7: Do the same for the ends of the wires on the (new) bi-metal strip.

8: Take the ends of the wires belonging to the (new) bi-metal strip and the wires coming from the main plug. Take the like-colored wires, and twist the bare metal ends together.

9: Twist on wire nuts, for both sets of wires. Make sure they are snug, with no bare wire showing.

10: Tape over the wire nuts with electrical tape. Tape over the wires nuts in a spiral fashion, completely covering the nut and both wires that are now spliced together. This will prevent accidental shorting.

11: Plug the main plug back into the rear wall of the fridge. Also re-connect the connectors to the evaporator fan and defrost coil. Make sure the clips on the connectors are snug to ensure a good connection.

12: Clip the new bi-metal strip onto the coils, in the same spot as before. ( Usually just after the small incoming copper tubing that connects to the coils, known as the expansion valve. That is usually the coldest spot on the coils during operation).

13: Replace the panel that covers the coils.

14: Plug the fridge back in... Now you fridge should defrost correctly. If it does not, your defrost coil could be burned out, or the control board could be faulty.
154 of 178 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Clint from Rayville, MO
Parts Used:
W11384469
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Lights inside refrigerator not working
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
118 of 192 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
LES from MADERA, CA
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Defrost timer was faulty. Required a mild tap to restart
Trouble shot the electrical circuit per the electrical schematic and zeroed in when I noted the Defrost Timer circuit was open. When I tapped on the bottom of the timer it began functioning normally (for a few days). Ordered a new Defrost Timer Kit and along with the installation instruction, I watched the on-line video. It was very helpful!!
After installation was complete, I plugged the Refrigerator into the electrical outlet and.......nothing happened! Hmmm!

Removed the Defrost Time Kit and inspected it for any damage and found none. Then I placed a flathead screwdriver to the manual advance knob and slightly rotate the gear mechanism. I heard a distance "click”. I believe the Timer was in the ‘defrost’ mode when received.

I reinstalled the timer, verified the wiring connections and this time plugged the Refrigerator into the electrical outlet and ….. it worked!!!

I unplugged the refrigerator, finished the installation per the instructions, plugged the unit in and monitored it for a few hours (just in case). That was a week ago and the Refrigerator is working like new.

The instructions were written in a manner which required re-reading a few times as they could be a bit vague. The video was what really helped and I appreciate PartSelect adding it to the instructions.
66 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald A. from ORLANDO, FL
Parts Used:
W11510803
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Wanted to install ice maker in my freezer
I was clening my uprght freezer and noticed that it was preped for an icemaker. I first went to the Whilpool website and could not find my part as my freezer was a 2008 model.

I saw PartSelect on the search page and went to thier site.
I put in my modle number of the Whilpool Ice maker kit that was on the back of my freezer. PartSelect had the part in stock and approx $18.00 less than the other kits listed on the Whilpool site (that did not match my kit number). I orderd the kit on Sunday and it arrived on Wednesday. It took less than and hour to install. Every part I needed was included. The following day I installed the water line and now I have an extra icemaker.
74 of 105 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Bradenton, FL
Parts Used:
W10822278
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Freezer Iced up, dripping water into refrigerator below
De-iced the refrigerator. Removed two screws from the thermostat panel on the upper refrigerator section. Tilted it down, removed two speed nuts holding the timer, unplugged the timer plug. Determined from the instruction sheet (easy to follow) what time delay function is used, based on wire colors, placed the jumper on the correct terminal on the new timer. Plugged it in, replaced the speed nuts and screws. The timer fit perfect, works just like it is supposed to, quick easy job.
61 of 72 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
DANIEL from MINNEAPOLIS, MN
Parts Used:
4387478
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Light Would Not Go On In The Refrigerator
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
61 of 77 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Lynn, IN
Parts Used:
WPW10225581, W10822278
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers, Socket set
Refrigerator too warm, freezer coil iced up
Unplug the refrigerator first,then Remove shelves and back inside cover from the freezer. Cut old bi-metal thermostat off and installed a new one. This fixed the problem. Ordered a new timer also which I didn,t need but installed it any way. On the fridge side ,top front, removed the knobs and cover, R&R timer, installed cover and knobs. Pay close attention to the instructions on where to put the black wire on the new timer. My refrigerator works great now. This was easy to repair if you are handy with electrical and mechanical repairs, if not get some help.
52 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Donald from Waco, TX
Parts Used:
WPW10188389, WP2264462
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The freezer section was working fine. Not properly cooling the refrigerator
I looked on line to see what was causes of the problem and determined that it was probably the fan in the freezer not working. I took the back section of the freezer apart and saw the fan was not running. I checked the parts on line and found that it was availiable and ordered a new fan motor. The blade looked fine, but I ordered a grommet anyway to ensure that there was no vibration problems causing the fan motor to go out. When the fan motor arrived, I began disconnecting the old one after unpluging the refridgerator and noting the terminals for the wires. The wire terminals were in a slightly different location, but reasoned out which wire belonged to the correct location. I pulled the old fan motor out, switched out the fan blade and grommet and re-incerted the new fan motor. I reconnected the wires and re-assembled the rear wall of the freezer. I plugged in the refridgerator and wa-la! It worked.
44 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James Richard from St. Cloud, MN
Parts Used:
W11384469
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Light Switch broke
An easy job for smaller hands. Removed the two bolts holding the light cover. Removed two electrical connections from the old switch by pinching the retaining clip,removed the switch, snapped in the new one and re-attached the connectors. Your online illustrations helped me to know that the plastic housing for the light switch would only swing down so far and was not intended to be removed. Saved me from breaking that plastic cover's tabs. This home repair saved me more than 5 times the cost of hiring a professional to do it. Very happy homeowner.
44 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Plano, TX
Parts Used:
W10822278
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
Timer "clicking", indicating worn gears
1. Unplug refrigerator to remove power!
2. The timer is inside the control housing located at the top of the refrigerator compartment.
3. Remove two control knobs (the pull off).
4. Remove the front panel escutcheon. The panel is not held in place with screws, but can be gently pried off.
5. Remove two screws from the back that hold the housing in place.
6. Remove screws from the front that hold the housing in place.
7. Drop housing down (still attached by wires - do not detach). Timer is inside housing, located on right.
8. Follow the instructions provided to identify your particular wiring setup. You'll find the wiring diagram (on my model) at the bottom of the refrigerator, alongside the defrost catch pan, behind the airflow grille.
9. Remove connector from timer terminals (4).
10. Remove two screws/nuts that hold the timer in place.
11. Install replacement timer following included directions. Read and follow ALL instructions applicable to your particular model and wiring setup.
12. Reassemble by reversing the steps above.
13. Note: You may need to "jog" the replacement timer when you first plug the refrigerator back in, if the timer happens to be in a "defrost cycle" (the compressor won't start). This can be done by inserting a wide bladed screwdriver into the hole below the timer, aligning it with the timer shaft, and slightly turning the shaft CW. Don't force it, and don't turn it very far.
37 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michelle from Richardson, TX
Parts Used:
72017
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Scratches in Surface
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
64 of 125 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Doral, FL
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Refrigerator Wasn't Cooling,Evaporater Coil Freezing Up
I have a side by side so in order to access the bi-metal switch I first had to empty out the freezer. The switch is clipped on to the top of the evaporator coil. I had to remove 8 screws to remove the back panel of the freezer compartment. The bi-metal switch was right there in plain view. There are two colored wires that come out of the switch. I tried pulling them out of the socket they were plugged into but gave up for fear of breaking something. I ended up cutting the wires and splicing them together. I used the plastic twist caps. I made sure when I closed everything back up that the open end of the caps were pointing down so no water can accumulate in them. It has been 3 days now and so far so good
38 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James from Ringoes, NJ
Parts Used:
WPW10225581
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
Auto Defrost Freezer keeps defrosting SIDE BY SIDE KITCHENAID
DISCONNECT POWER. Removed all shelves/baskets.Popped upper panel off (just clips in) Removed 6 screws in lower back panel ( 3 each side) slid panel in place but down. You can then easily see the defrost thermostat/defrost termination switch. Cut the wire connectors (pink n brown wire) stripped back wire, attached new defrost thermostat. Thermostat clips on. New thermostat ohm's at 5.5, old one was "open". Slid cover back up meeting the upper cover grooves. Screwed lower panel in. Put shelves etc back in. Plugged in. Turns on, put a bottle of water in freezer. Checked a while later, frozen. has been frozen for a week.
-James
37 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Joann from ATCHISON, KS
Parts Used:
WP2263749
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Freezer wasen't cooling refrigerator
Removed the old defrost heater screws and connected the new one. I have 46 apartment units here and have had about 15 defrost heater's replaced by service repair person at a very expensive cost. To my surprise it was extremly easy and a lot less in cost.
34 of 43 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the A4TXCGFBW00