Sometimes the condenser fan would start causing the refrigerator to overheat.
Unplug the appliance.
Removed the screws holding the back panel.
Removed the fan blade.
removed 3 screws holding the condenser fan.
Remove the 3 metal brackets attached to the fan.
(First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied)
Cut and strip the wire about two inches from the fan.
Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws)
Screw the back panel back on.
Mount the new
183 of 219 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Peter from Eden, UT
Parts Used:
R0131577
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Socket set
Fridge and freezer didn't cool enough
I diagnosed the problem via the internet. Diagrams helped a lot. Coils were frozen over. Thawed them out overnight. Manually advanced timer and the defrost heater was operable. The defrost timer wasn't "turning" on it's own. I turned the fridge back on while I awaited the part. It worked fine for the time I had to wait. (over two weeks since I had delayed ordering the part) New timer arrived as promised. Undid 4 hex head (1/4") screws. Unplugged 4 prong connection. Plugged in new timer and replaced the 4 screws. Frigde works great.
106 of 117 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from North Attleboro, MA
Parts Used:
4318046
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers, Socket set, Wrench (Adjustable)
Outlet valve housing was cracked and leaking water
Removed panel in back of fridge. Disconnected water line. Removed outlet valve housing and disconnected wiring. New part is a retro-fit and was modifiable to fit into same space as old part. Reconnected wiring and water line. Turned water back on to test. Checked water dispenser in front door panel. All good. Replaced panel and wheeled back into place.
65 of 71 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
robert from nashotah, WI
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
noisy fan motor
rmv panel (5min) rmv fan/motor 3 screws (10 m) cut wire 2in from motor, re route remainder of wire to front so can strip for wire nuts. ( 10m) attach old fan to new motor, place in old opening ,3 screws, a little fussy to align, ( 15m ) route and strip wire from new motor , zip ties work well, wire nuts , plug in fridge vola, no noise, close up, reverse panel. ( 20m). i also took time to clean grilles with small vac and damp rag, ( looks and sounds like new) bob Wi.
38 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Janet from Hillsboro, OR
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
24 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Florentino from Windsor Locks, CT
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bill from Hot Springs Village, AR
Parts Used:
4318046
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Wrench set
Just a trickle of water to icemaker and water dispenser
Turned refrig off, pulled it out for access to the valve, unplugged refrig and turned off water supply to the outlet valve. I made the installation a bit more difficult by over tightening the supply line connection which ruined the brass compression washer. I replaced it with a plastic compression washer which is probably better since the supply line is plastic. The electrical connections were very simple. I was just guessing the old outlet valve was bad since I had checked the filter. After replacing the valve, the ice maker and water dispenser work like new on a 17 year old refrigeration. Also, I was very pleased with fast processing and delivery of the order.
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
W from Nellysford, VA
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Bob from Hesston, KS
Parts Used:
833697
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Socket set, Wrench set
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
24 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Alexander from Miami, FL
Parts Used:
4318046
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set, Wrench (Adjustable), Wrench set
Ice maker water outlet freezes and prevents flow
Get refrigerator out away from the wall. Disconnect from power. Loosen 3 and remove 3 or 4 screws to uncover fan, compressor and water inlet valve (WIV). By hand remove plastic hoses that feed the water dispenser and ice maker feed. Unscrew 2 screws that hold WIV her you need the Spring U Joint (SUJ) or equivalent. Pull wires and make mental note or picture the way they fit. They retain the memory the way they came out. With adjustable or wrench remove tube that comes from the filter. Remover black rubber protector from WIV. Install the last hose you removed. Tighten by hand and finish with the wrench used to remove it. Don't over tighten. Maybe 3/4 turn or less after hand tight will do. The difficult part is to re-install the screws that hold the WIV in place, again you need the SUJ. The alternative would be to empty the shelves from anything that will spill or break and have someone tilt the refrigerator and access from below. I used the 1st method as I didn't have the extra help. Install the water dispenser hose (by hand), blow compressed air to the ice dispenser hose to clear the ice. There is another plastic hose just above and behind the dispenser which must be removed to clear the ice that is being blown. After the ice is clear re-install the one in the freezer. That one is just pressure held be careful not to break when replacing it. Re-install by hand the ice dispenser hose to the WIV. Replace the cardboard cover that was 1st removed to access the components. Power the refrigerator and you are ready to make fresh ice. My ice maker lever was stuck at 1st. I released pressure from the metal wire lever and wiggled up and down several times to loosen up.
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
David from Cedarville, OH
Parts Used:
833697
Difficulty Level:
A Bit Difficult
Total Repair Time:
More than 2 hours
Tools:
Screw drivers, Socket set
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Charles from Sacramento, CA
Parts Used:
4318046
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Socket set, Wrench (Adjustable)
Water dripping from door dispenser
The part received was a straight replacement part - no modification required, just a simple remove and replace. This made the job really easy. Used the socket set to lower the front wheels to move the refrigerator, the nutdriver to remove the back cover and the valve, and the adjustable wrench to remove the water line. I had to cut the supply line tubing because the ferrule was too far up the line to make a good seal (minor leak quickly corrected with parts available in the kit - nice touch!) What took the most time was cleaning the coils and lint, etc. - hey I hadn't moved the unit in years! - but I did not include the 45-60 minutes this took in the repair time. Directions supplied were clear and easy to follow - but in my case I could have done the job without them - easy to see what needed to be done, but the stated precautions were nice.
12 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Walter from Willis, TX
Parts Used:
4318046
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
No water to icemaker
The replacement valve was identical to the old one, so I didn't have to use any of the adapter parts sent with the new valve. This made the installation rather simple. After removing the back cover on the lower part of the refrigerator, I turned off the water and electrical supplies, and removed the water supply line to the valve. Then I removed the two screws securing the valve to the refrigerator. Next, I removed the two electrical connections from the valve, and unscrewed the plastic nuts holding the tubing to the valve. I didn't have to use a wrench to do this as they were hand tight, so when I attached the tubing to the new valve I tightened the nuts hand tight. This seemed to be sufficient and avoided the possibility of stripping the nuts. After checking for leaks, I attached the electrical connections and secured the new valve to the refrigerator. Then I attached the water supply line, but before replacing the back cover, I turned on the refrigerator, and let it cycle through it's first load of ice.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
THOMAS from STOW, OH
Parts Used:
WPA3073101
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
burnt out bulb
took cover off, installed bulb.
lost the owners manual,
part select's schematics were very helpful
thanks
27 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Benjamin from Daytona Beach, FL
Parts Used:
833697
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Pliers
Condenser fan motor seized
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation.
I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill.
Done
Total time of ice maker water leak repair and fan replacement about 1 hour.
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CSDI25C-L-P73320-52WL
1 - 15 of 141