Models > CRG7500CGL > Instructions

CRG7500CGL Maytag Range - Instructions

Jump to:

All Instructions for the CRG7500CGL
1 - 3 of 3
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Philip from Houston, TX
Parts Used:
WP7730P011-60
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Indicator Lens melted and fell back into the control panel
I took the back panel off, removed the old lens, installed the new lens. How easy to order from home, receive the part, do the repair and pay less than it costs to simply drive to the parts house. Cool....
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Harold from Russell Springs, KY
Parts Used:
WP74004153
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers, Socket set
Hot burner light went out
Unplugged the range, took off back shield (4 screws) unplugged the old part and plugged the new part in, put the shield back on and plugged the range back in. When you remove the light unit behind the lens after unplugging the two contacts slide it sideways toward you, it is slotted, don't try to pull it straight out or you will break the lens.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Ashley from Bel Camp, MD
Parts Used:
WP7730P011-60, WP74004153
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Socket set
My burner on indicator light had stopped working
I ordered both the light bulb and the switch that controls it. I had not pulled the stove out because the ones I bought this house from did not level the floor which meant I had to wait on a socket set to arrive in order to be able to pull my stove away from the wall. Once I got the socket set and the stove out I removed the panel on the back. I saw then that my red light bulb had shattered in half forcing the switch to just hang free. Glad I had ordered both parts, removed the old, replaced new with ease... then it was a matter of sliding the panel back in place without the main control panel getting misaligned, few trial and error checks and it went back with ease. New light works! Very easy.. probably less time if your floor is level.. then I had to play with the little legs to get it even again. For now it is ok until the spring where I go to redo the floor and make it all LEVEL! Very easy! Hope it doesn't burn out again but if it does I know what to do! Maytag rep wanted to charge me $100... No thanks!
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CRG7500CGL