Customer:
Thomas from Andover, NJ
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Microwave runs with the door open
Remove microwave outer cover. Turn on side & locate the upper & lower door switches. Better to replace in pairs even if one is ok. Remove the wire harness to each switch. Then replace switch and re connect the wire harness. Re attach outer cover
and test to see if that solved the problem. If so then well done!!
35 of 50 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Michael from Ridgefield, CT
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Microwave would turn on and count down, but not heating and not rotate turntable. Pressing door up would occasionally start heat.
First I disconnected the power and opened the door. Then I removed the top screws holding the top vent louvers, then removed the screw at the top of the touch pad. The touch pad removes by sliding up slightly then tilting top out. I unscrewed two screws holding the door latch assembly. Press the tab to remove and replace switch. Reconnect wires, reseat latch mount by placing top bracket tab in place first, allign and secure with screws. Reseat touch pad by placing bottom tabs in first, tilt forward and press up to seat top tabs, secure with top screw. Secure vent louver screws, plug in and watch your microwave work again.
37 of 58 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Keith from Bowling Green, KY
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Everything seemed to work with the controls, but when you pressed start the light would come on and nothing else. The turntable and heating system would not function.
I unplugged it, removed the outer shell with torque bits and a screwdriver, drained the main capacitor, and began debugging the circuit with my fluke multimeter, found the bad primary interlock, googled the part number, ordered the part, received it in 2 days, replaced the interlock in about 2 minutes, and put the cover back on. Fixed. Saved me about $200 over buying a new unit and was grateful for partselect's great service.

-Keith Packard
25 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from Dayton, NV
Parts Used:
WB27X10037
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Microwave would not heat food
First and most important - unplug AC power 24 hours before service.

I removed the vent cover above the main door, then I removed the screw which holds the control panel in place, unplugged the main connector on the control panel so I would have enough room to work, removed grounding screw from the DIODE ASSY, pulled connector off the CAPACITOR with pliers, installed new DIODE ASSY.

After installation of DIODE and the control Panel, I plugged in the AC power and allowed the CAPACITOR to charge - this takes about an hour or so, then test. Works perfect!
17 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lawrence from East Patchogue, AL
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
had to press door opener slightly to work
Removed screws holding outer shell. Pushed in door handle to identify faulty switch. Ordered part. Pryed switch out with screw driver and unplugged. reinstalled new switch. Presto. BUT... I did NOT use both hands while working on the microwave. I did not release the energy from the capacitor or whatever holds the killer amperage even when unplugged. It would be advisable to do this first. I did not because it seemed complicated, so I was EXTREMELY CAREFUL about not touching anything else inside the unit. I used one hand only so if I did touch something I would not get juiced through the chest. It was a piece of cake repair, but I would not go deeper without doing the discharge routine.
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from Goshen, IN
Parts Used:
WB26X31060
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
Blower Fan quit working
It took a while to remove approx 30 screws to get to the blower. So my oven was sitting, torn apart while I waited on the new blower fan that I had ordered. It arrived shortly, about 5 days. When I opened the box I saw that PARTSELECT had sent me a drain pump instead of the blower fan that I had ordered. Since an oven does not require a drain pump and it wouldn't work to replace my broken blower fan I had to return it. I was told that I needed to send the part back in order to get a refund. After I sent their drain pump back at a cost of $13 they emailed me and said I didn't need to send the drain pump back. And they refunded me minus shipping So I had to pay shipping both ways for a part that was wrong. And I ordered it from someone else. I put the new blower fan that I had bought from another company in and replaced the 30 screws. And the oven has been working fine ever since. Thank you PARTSELECT for allowing me to tell people how you operate. They have a money back guarantee, but they don't give you back ALL your money. Thanks Again.
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Norbert from Minnetonka, MN
Parts Used:
WB24X10047
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
No cooking Power
Had to remove outer cover (special screws involved). Found the correct part at PartSelect.Com and it arrived 3 days later as promissed.

This oven has diffcult electrical connections at switch to get disconnected. I found it easier with the sw loose and in hand so that the connectors can be released with a small screwdriver.

One has to this in order to test the part wirh an ohm meter. I found the sw did not close but remained open and thus caused the oven not to function.

Removing interconnect switch is tricky but not difficult.

Outer cover replacement is not as easy as it should be, especially the sides.

All is well and working.

Microwaves are simple devices if you are know how to read and understand schemetic diagrams.
12 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Javin from Waltham, MA
Parts Used:
WB26X10193
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Turntable did not turn when anything on top
Turn off the circuit breaker to the microwave. Remove the 4 black wood screws that secure the microwave to the cabinet. Pull the microwave all the way out and set it on something that leaves you access to the middle access panel on the bottom. Remove the access panel on the bottom that has one screw. Unhook the 2 cables to the motor remembering which color goes where. Remove the 2 screws for the motor and replace the motor. Finish up in reverse...
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Salih A. Hindas / DHA from SPRNGFLD GDNS, NY
Parts Used:
WB26X31060
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Clear Error Code F96
Changed Fan Blower only, which cleared the Error Code F96.
Other parts have been kept as spares.
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Darrell from ACWORTH, GA
Parts Used:
WB26X31060
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Screw drivers
Fan blower error on oven, oven would not work or
Turn power off to oven, removed screws holding oven into cabinet, get assistance to remove oven, I used 2 dinner table chairs to set the oven on, be careful as the front of the oven is heavier than the back. Removed the back sheet metal covers, about 20 screws or so. Removed Fan motor, replaced with new fan motor, and reversed installed. Oven works great.
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Aaron from BLUE RIDGE, TX
Parts Used:
WB26X32629
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Microwave function not working
1) Removed 4 screws securing the microwave to the cabinet.2) Slid microwave out, unplugged and placed on a work surface that allowed lower trim to hang over. 3a) Removed two screws and removed the cover on top of the oven. 3b) Unplugged high voltage plug from Magnatron. 4) Removed wires from overtemp fuse mounted to Magnatron. 5) Removed the four screws securing the Magnatron to the oven. 6) Removed Manatron. It's a tight fit, but can be done without removing anything else. 7) Replaced Magnatron. This is where I needed the magnetic part retrieval tool. The nature of a Magnatron is the use of strong magnets surrounding the tube. Getting the four screws back into place wasn't possible with just a normal magnetic screwdriver tip. I used the retrieval tool to position the screws back in place. Be sure to not initially tighten any screw completely, until they can be evenly tightened. This ensures correct compression/seating of the shielding material near the neck of the tube. 8) Reverse removal steps. Plugged in and tested microwave function on a cup of tap water. 9) Reinstated in cabinet and got a big thank you kiss from the wife!
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Erie, PA
Parts Used:
WB24X10047
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
microwave would not heat
First remove all screws holding on outer metal casing of microwave. Next remove the back and bottom metal pieces. You will then be able to pull aside the outer casing so you can access the door switches. Check each switch with an ohm meter in both the open position and with the switch closed. If the ohm meter reads the same in both the open and closed position, the switch is bad. Check the top switch first. Replace switch and reassemble. Cheap fix for a costly microwave. Great customer service at Parts Select!
13 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Reid from LITTLETON, CO
Parts Used:
WB26X32629
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Sparking from the magnetron
Symptom: Terrible sparking coming from the right side of the microwave even with nothing in the microwave. The part that was behind the cover was the business end of what I learned was the magnetron,

Repair process: Without appliance repair experience I went onto Google and searched for parts for my model PEB1590DM2WW. I was able to find a great parts schematic on partselect.com. At first I ordered a magnetron and while waiting for the parts to arrive I also learned that the capacitor can also fail easily as described in the other install feedback on the partsselect website. So I ordered a capacitor just in case. These convection microwaves are around $600 new so a $80 in parts is not out of line for 8 years of service.
I installed the magnetron first and turned it on. sparking immediately continued so I quickly shut the unit off. After replacing the capacitor and letting it charge for several minutes before trying to start the microwave cycle was the issue. I choose to leave the replaced magnetron as the original unit was discolored and felt the replacement was inexpensive insurance. I also learned that if the wave guide (which is a plastic/metallic composite material) that covers the opening to the magnetron is burnt or has metal melted to it as mine did it will act similar to the microwave having metal inside the enclosure and will continue to spark and basically melt the wave guide further. Replacing the wave guide was very easy as well.

I am very thankful for the knowledge base and support available from Partselect.com as they made this repair possible on my own. Thank you partselect.com
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Don from BATON ROUGE, LA
Parts Used:
WB26X31060, WB27T11463
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Nutdriver, Socket set
F97 code
Replaced upper cooling fan and board on double oven by removing covers on top and back.
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Henry Totten from GROVES, TX
Parts Used:
WB24X10047
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Opened door to get food put more food in closed door it wouldnt work
Everything worked on the display light inside worked but when you closed the door and set time it would start counting down but not heating nor would the turntable turn. Started reading troubleshooting chart and first thing I did was removed the cover and checked door switches and found primary door switch wasn't working so I ordered a new one installed it and it worked. Anyone doing this has to be very careful because of the stored energy in the capacitor is strong enough to kill.
My micro is only 2 years old so I was hoping it wasn't anything major.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PK7800EK5ES