Models > FCFI3083ASA

FCFI3083ASA Electrolux Range

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for FCFI3083ASA

Viewing 4 of 4
Keep searches simple, eg. "belt" or "pump".
This range terminal block kit provides a secure connection point between the household power cord and the appliance’s internal wiring. It helps distribute electrical power safely and reliably to the r...
In Stock
Order now and your part arrives by Mar 19
In Stock
Order now and your part arrives by Mar 19
$56.05
Measurements: approximately 22 7/8" x 16 1/4"
In Stock
Order now and your part arrives by Mar 19
$45.27
In Stock
Order now and your part arrives by Mar 19
$24.10
In Stock
Order now and your part arrives by Mar 19
In Stock
Order now and your part arrives by Mar 19
In Stock
Order now and your part arrives by Mar 19
$20.95
Special Order
$7.30
In Stock
Order now and your part arrives by Mar 19
In Stock
Order now and your part arrives by Mar 19
In Stock
Order now and your part arrives by Mar 19
$75.95
In Stock
Order now and your part arrives by Mar 19

Questions and Answers

Be the first to ask our experts a question about this part!

Common Problems and Symptoms for FCFI3083ASA

Viewing 1 of 1
Will Not Start
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Fred from North Babylon, NY
Parts Used:
5303935271
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Pliers, Screw drivers
left terminal broke off from the base of the block causing circuit breaker to trip and not able to be re-set
Ensured breaker was off. My range is hot wired. Removed all cables from old terminal block with nutdriver. Used phillips head screw driver to remove old terminal block from back of range. replaced old terminal block with new one. Re-attached accessory cables to small terminals first, then the main cables to the terminal block using where necessary long nose pliers. It is important to make note of which cables are attached to each terminal of the block, so make a sketch PRIOR to removal. Also be careful how the cables are attached to the block. You are using 10 gauge cable with thick insulation. It is important that when pushing the range back into position the cable does not put too much pressure on the block as it will break it. That's exactly what happened to this last one. It probably cracked under the strain of the pressure of the cable and finally current running through it weakened it to the point where it broke off from the block causing it to short and trip the breaker.
0 of 6 people found this instruction helpful.