Models
>
PT125VGFA
PT125VGFA Pro Temp Heater
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for PT125VGFA
Viewing 1 of 1Keep searches simple, eg. "belt" or "pump".
On Order
In Stock
On Order
On Order
On Order
In Stock
In Stock
Special Order
Special Order
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Dan
January 20, 2023
Heater stays lit as long as i hold the button in no matter how long i hold it in when i let it out it goes off what part should i change
For model number PT125VGFA
Hello Dan, thank you for contacting us. We would recommend checking the spark module, part number FIX10468874, and the PCB, part number FIX10468868. These are the most likely culprits. Customer service is available 7 days a week if you require assistance placing an order. Thanks again for reaching out!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Related Parts: