Models > EP2205

EP2205 (0295024) SprayTECH Paint Sprayer

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for EP2205

Viewing 10 of 10
Keep searches simple, eg. "belt" or "pump".
This replacement on/off switch is specially manufactured for use on Titan and SprayTECH sprayer pumps. The purpose of this switch is to allow user to turn the equipment on and off. Over time mechanica...
On Order
It is a genuine item that is supplied by the original equipment manufacturer for use with Titan airless sprayers. The purpose of this o-ring is to provide an air-tight seal for the siphon elbow, over ...
In Stock
Order now and your part arrives by May 9
No Longer Available
It is a genuine replacement part that is specially designed for use with SprayTECH and Wagner pumps. This o-ring helps to create and air-tight seal for the filter, for correct application make sure to...
In Stock
Order now and your part arrives by May 9
$13.12
In Stock
Order now and your part arrives by May 9
$6.51
It is a genuine item is supplied by the original equipment manufacturer for use with Titan and SprayTECH sprayers. This is one of the special plugs for the cart. The part helps to provide cushioning h...
In Stock
Order now and your part arrives by May 9
$107.20
Special Order
In Stock
Order now and your part arrives by May 9
This is an original Wagner replacement part. The prime spray valve is used in Wagner pumps to control the flow from the transducer assembly. This kit contains a metal spring, two retaining clips, a ...
In Stock
Order now and your part arrives by May 9
Special Order
In Stock
Order now and your part arrives by May 9
Special Order

Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

1 question answered by our experts.
  • 1
Sort by:
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Mike
November 15, 2023
Having trouble with suction. Not priming
For model number EP2205
Fix.com logo
Hi Mike, thank you for the question. Rotate the PRIME/SPRAY valve clockwise to the PRIME position. Check the siphon tube/suction set connection and tighten or re-tape the connection with PTFE tape. Remove the pump filter element and clean. Remove the inlet screen and clean. Remove the siphon tube/suction set and clean. If the issue still persists, you will need to replace the prime spray valve kit, part number FIX10505099. We hope this solves your problem!