Models > MT9160XYB1

MT9160XYB1 Whirlpool Microwave

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for MT9160XYB1

Viewing 6 of 6

Manuals & Guides for MT9160XYB1

Click to download
Keep searches simple, eg. "belt" or "pump".
$20.79
This is a screw and it is made for multiple appliances in your home. This model is called a sheet metal screw because it has sharp points, and the threads are closer together. This screw is designed t...
In Stock
This kit contains 2 switches - 15 Amp - 125/250 Volt with 3/16" terminals.
In Stock
Sold individually.
No Longer Available
This screw is for microwaves. A qualified technician should install this part if it requires accessing internal components of the microwave or microwave door. High-voltage capacitors can retain a l...
Special Order
This part guides the waves to the inside of the microwave to cook your food.
No Longer Available
$12.60
In Stock
No Longer Available
In Stock
Special Order
$31.53
Special Order
This part allows power to go one way but not the other.
No Longer Available
In Stock

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Problems and Symptoms for MT9160XYB1

Viewing 2 of 2
Won’t turn on
Fixed by these parts
Fixing
How to fix it
Doesn’t shut off
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Robert from Bainbridge Island, WA
Parts Used:
4392027
Difficulty Level:
A Bit Difficult
Total Repair Time:
30 - 60 mins
Tools:
Pliers, Screw drivers
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and a lso took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
67 of 82 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert S. from Stafford, TX
Parts Used:
4392027
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Close the door on the microwave, punch in the # nothing happened
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me.
The parts was delivered almost before my notice they were shipped.
15 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Dale from Chester, CA
Parts Used:
4392027
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
Fan motor and magnetron did not come on, but every thing else did.
Problem would come and go. Found service schematic inside unit. Perform all the suggested tests. One possible solution was the primary interlock switch shown on the schematic and a check found the switch stuck. It would free up some times but would stick again in the open position. Ordered switch which was a simple plug in unit.
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!