- Customer:
- Duane from Jacksonville, FL
- Parts Used:
- WP10794402
- Difficulty Level:
- Very Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Screw drivers, Socket set
Magnetron shorted out blowed 15 amp fuse
removed cover of microwave, replaced fuse checked for short at plug with volt ohm meter, there was a short at the plug then checked magnetron for short and there was a short at the magnetron, the cap and diode checked good.
replaced magnetron IT IS WORKING GREAT !!
replaced magnetron IT IS WORKING GREAT !!
Was this instruction helpful to you?