Customer:
Duane from Jacksonville, FL
Parts Used:
WP10794402
Difficulty Level:
Very Easy
Total Repair Time:
1- 2 hours
Tools:
Screw drivers, Socket set
Magnetron shorted out blowed 15 amp fuse
removed cover of microwave, replaced fuse checked for short at plug with volt ohm meter, there was a short at the plug then checked magnetron for short and there was a short at the magnetron, the cap and diode checked good.

replaced magnetron IT IS WORKING GREAT !!
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!