Models
>
UMC1071AAW
UMC1071AAW Maytag Microwave
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for UMC1071AAW
Viewing 4 of 4Manuals & Guides for UMC1071AAW
Click to downloadKeep searches simple, eg. "belt" or "pump".
In Stock
Order within the next 6 hrs and your part ships today!
Special Order
In Stock
Order within the next 6 hrs and your part ships today!
In Stock
Order within the next 6 hrs and your part ships today!
In Stock
Order within the next 6 hrs and your part ships today!
In Stock
Order within the next 6 hrs and your part ships today!
In Stock
Order within the next 6 hrs and your part ships today!
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Problems and Symptoms for UMC1071AAW
Viewing 2 of 2Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- John from Inverness, FL
- Parts Used:
- WPY01050009
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Blown Fuse - Ps1750182
Unscrewed the cover of the microwave replaced the blown fuse with the new fuse, plugged in the microwave and tested all functions and everything worked fine. Thx for quick delivery.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- patricio from chicago, IL
- Parts Used:
- WPY01050009
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Nutdriver, Screw drivers
no power at all
unscrew microwave's cover,test the fuse which is located at top rear left side, the fuse is inside a plastic tube,if the fuse is burnout,just replace it.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- TIFFINI from BUFFALO, WY
- Parts Used:
- WP3405-001034
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave would continue to run even when door was open. (even if no time was left on timer)
Unplugged Microwave, Removed vent cover (2 screws on top of microwave, then slide cover to the left, then forward) Removed control panel (1 screw at top of panel) then removed the two screws that hold in the door switch assembly. (these you will only see by opening the microwave). Located lower door switch, removed connecting wires, and
... Read more
pulled switch by releasing small plastic tab which held it in. Put new switch in place, reconnected wires, then reconnected door switch assembly. Reconnected control panel, and then put the vent cover back on. Tested microwave and it no longer runs when the door is open. Super easy fix, and was done in under 5 minutes.
Read less
Was this instruction helpful to you?