If the vent grille for your microwave has become broken or damaged, this is a genuine OEM replacement part. The vent grille is made of black plastic and measures approximately 24 inches long and 3.5 i...
This charcoal filter in manufactured to fit a microwave. It removes food odors from the air circulating through your appliance vent. Youi may need to replace this part if you notice odor when cooking ...
This bracket holds the metal or plastic flapper that closes off the exhaust duct when the fan is not running and opens when the fan turns on. If the exhaust fan on your microwave does not appear to be...
The locker, or door latch assembly fits to the inside of the microwave door, and keeps the door closed. If the door on your microwave oven doesn’t appear to close properly, you may have a problem with...
This metal vent damper door closes off the exhaust duct when the fan is not running to stop outside air from entering the microwave unit, and opens when the fan turns on to allow air to vent away from...
This part is the replacement base plate trim, also known as the front décor for your microwave. It is gray in color and is approximately 30 inches long and 1 ½ inches wide. The base plate trim forms a...
If your microwave hood isn’t staying in place or the door won’t close properly, this catch lock may be the issue. Designed for LG slide-out hoods, it helps secure the hood during use. This part is sol...
Ask our experts a question about this part and we'll get back to you as soon as possible!
2 questions answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched. Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Doug
June 16, 2022
Doesn't seem to be any power to microwave. Clock doesn't work. There is power at the receptacle.
For model number LMHM2017ST
Hello Doug, Thank you for contacting us. This could be an indication the Fuse has Blown. We have researched the model you have provided and have found the part you are looking for is Fix Number: FIX3522741. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you!
Microwave only start when I close door then put pressure at top of door pushing inward
For model number LMHM2017ST
Hi Luis,
Thank you for your question. If the microwave starts when you close the door, we would recommend checking the door switches, the latch, and the door to see which part is causing the issue. We hope this helps!
After watching a few youtube videos, I used a phillips SD to take controll pannel off to access the switches that sense when microwave door is closed. Swapped out all 3 switched and mocrowave works like new. $20 fix (shipping included)
Unplug the unit before servicing. Need phillips screwdriver. Open door. Use step ladder to access and remove 2 small screws from top of the room air diffuser at top of unit. Slide diffuser slightly to the left to align the diffuser's plastic tab on the left side to rotate toward you. (The wires for the front control panel are at the far l
... Read moreeft side of this difuser, but difuser is slotted for easy removal). Once the difuser is removed you will see 1 screw at the top that secures the pannel cover on the left side of the unit. Remove screw and slide this panel slightly up and out. This exposes the plastic frame that holds the upper and lower door switches. To locate the door switches and observe how they work, close and open the door and watch the door (bayonets) open and close the micro switches. Do the (red) buttons on top of the switches move up and down when the door bayonets push and release? If the buttons do not "pop" up when opened the switch is defective. The switch frame is secured with 2 screws. Remove screws and rotate the unit out for easy access to the micro switch(s). The internal (spring?) on my unit that is suposed to allow the red (visible) button on top of the switch to "pop" up when the door is opened was broken. Carefully pry the switch outward while being careful to lift the plastic holder-piece that holds the switch in place. Be careful, there is a small pin on the frame, so rotate the switch OUT toward you while lifting (carefully) the plastic holder-piece (you will see it on top of the switch). You can use an ohm meter to test the continuity of the switches. But if the buttons don't "pop" they are defective. Replace switch and reassemble.
Leave the unit installed. Remove 8 screws, 4 on each side of the bottom of the drawer. It is hinged on the back but front will drop down. Remove screws attached to the white slide rails but hold bezel assembly so the spring metal on each side do no break. Look in assembly from the back to front. With a long Phillips remove the screws hold
... Read moreing the bezel on. 3 screws. Remove old Bezel. Put new on and reassemble using the reverse.