Models
>
ZSC2000FBB02
ZSC2000FBB02 General Electric Microwave
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for ZSC2000FBB02
Viewing 7 of 7Manuals & Guides for ZSC2000FBB02
Click to downloadKeep searches simple, eg. "belt" or "pump".
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
NOTE: This is a manufacturer substitution. Part may differ in appearance and size but is a functional equivalent to prior part.This tray rotates in your microwave ensuring more even temperatures.
No Longer Available
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
In Stock
Order within the next 12 hrs and your part ships today!
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Problems and Symptoms for ZSC2000FBB02
Viewing 4 of 4Won’t turn on
Fixed by these parts
How to fix it
No heat
Fixed by these parts
How to fix it
Tray won’t turn
Fixed by these parts
How to fix it
Doesn’t shut off
Fixed by these parts
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Thomas from Andover, NJ
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Pliers, Screw drivers
Microwave runs with the door open
Remove microwave outer cover. Turn on side & locate the upper & lower door switches. Better to replace in pairs even if one is ok. Remove the wire harness to each switch. Then replace switch and re connect the wire harness. Re attach outer cover
and test to see if that solved the problem. If so then well done!!
and test to see if that solved the problem. If so then well done!!
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Michael from Ridgefield, CT
- Parts Used:
- WB24X10047
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave would turn on and count down, but not heating and not rotate turntable. Pressing door up would occasionally start heat.
First I disconnected the power and opened the door. Then I removed the top screws holding the top vent louvers, then removed the screw at the top of the touch pad. The touch pad removes by sliding up slightly then tilting top out. I unscrewed two screws holding the door latch assembly. Press the tab to remove and replace switch. Reco
... Read more
nnect wires, reseat latch mount by placing top bracket tab in place first, allign and secure with screws. Reseat touch pad by placing bottom tabs in first, tilt forward and press up to seat top tabs, secure with top screw. Secure vent louver screws, plug in and watch your microwave work again.
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- James from OKLAHOMA CITY, OK
- Parts Used:
- WB02X10624
- Difficulty Level:
- Really Easy
- Total Repair Time:
- Less than 15 mins
Broken shaft -- turn table would not turn.
Safety TORX driver removed screw. Ceramic cover removed with ease. Shaft pulled straight up and out. Broken piece not retreivable and left in base of oven. New shaft inserted over "D" stub. Ceramic cover replaced and screw tightened.
When the ceramic cover is removed, this allows the glass cover for the UV heating unit to ... Read more be removed, cleaned, replaced. I recommend doing this.
When the ceramic cover is removed, this allows the glass cover for the UV heating unit to ... Read more be removed, cleaned, replaced. I recommend doing this.