Models
>
FPBM307NTFA
FPBM307NTFA Frigidaire Microwave
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for FPBM307NTFA
Viewing 3 of 3Keep searches simple, eg. "belt" or "pump".
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
On Order
In Stock
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
- < Prev
- 1
- Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Joel
December 6, 2021
Would my clock and light work if the fuse was blown?
For model number FPBM307NTFA
Hello Joel, Thank you for the question. When the fuse is blown, it will cut power to the appliance and it will not power on. There would be no lights or display. If you need help placing an order, customer service is open 7 days a week. Please feel free to give us a call. We look forward to hearing from you!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Related Parts:
Common Problems and Symptoms for FPBM307NTFA
Viewing 2 of 2Won’t turn on
Fixed by these parts
How to fix it
Door not closing properly
Fixed by these parts
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Arthur from LUTZ, FL
- Parts Used:
- 5304509460
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Microwave tripped circuit breaker when turned on
Remove vent cover then remove touch screen control panel. When you remove control panel take photo of where everything is plugged in then unplug and remove control panel. 3 door switches located next to door in a plastic chassis. Test each switch with current tester. Remove the bad switch and replace with the new one. You tube DIY helped.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- JOSEPH from MIAMI, FL
- Parts Used:
- 5304509457
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Power would not come on, would trip breaker when connected.
First thing I dir was search YouTube for any related videos and found this one https://www.youtube.com/watch?v=uHj4H9Fdxrc, it was the exact problem my microwave was exhibiting. Once I verified the problem by troubleshooting, I removed the part and verified that the switches were working fine, the door latch assembly showed signs of wear
... Read more
which was the cause of the problem. After receiving the replacement part I installed it, verified that power was restored to the unit and reassembled the microwave, works fine, hope it lasts a long time!
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- ARNEL from WAUKEGAN, IL
- Parts Used:
- 5304509460
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Pressing the start, microwave will start and dies out. Electric is tripping.
The diagnosis is about an hour. Coz, I need to open the control panel, got a tester, and trsted all critical parts inside the panel.
Also, replaced the fuse just to make sure its a new one. Found out it was a switch (bottom part) that control the open/close of the microwave door.
When found out the problem, the rest of t ... Read more he work is easy.
Also, replaced the fuse just to make sure its a new one. Found out it was a switch (bottom part) that control the open/close of the microwave door.
When found out the problem, the rest of t ... Read more he work is easy.
Read less
Was this instruction helpful to you?
Thank you for voting!