- Customer:
- Nancy from ST AUGUSTINE, FL
- Parts Used:
- 00617090
- Difficulty Level:
- Very Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Screw drivers
Microwave was sparking
Replaced the wave cover. Unscrewed existing cover that is at the top inside the microwave. Screwed in the new cover.
Took about 30 seconds to do. Bosch service wanted over $100 for a service call plus parts and labor. Did it myself in seconds for under $10.
Took about 30 seconds to do. Bosch service wanted over $100 for a service call plus parts and labor. Did it myself in seconds for under $10.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Brent from MINCO, OK
- Parts Used:
- 00631512
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Screw drivers
No heat and turn table did not turn
After going to a local parts store to get the correct switch, I replaced the right door switch. The correct switch is a normally open switch. The one shipped to me was a normally closed switch. Either Bosch provided the wrong description of the part required or someone at partselect needs to check the part stocked.
Was this instruction helpful to you?
Thank you for voting!