Customer:
Bruce from CARNATION, WA
Parts Used:
691656
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Wouldn’t start.
I installed a new solenoid starter. Took me a total of 20 minutes. Started right up.
10 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Laron from GRAND RAPIDS, MI
Parts Used:
192366GS
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver, Screw drivers
No voltage on secondary side of transformer. Confirmed with meter that transformer windings had infinite resistance.
1. Turn the generator selector switch to "OFF"
2. Remove the 240 volt fuses in the automatic transfer switch to remove power to the transformer.
3. Remove the outside cover from the front of the generator, on the motor end.
4. Remove the 3 screws from the panel covering the controls.
5. Label or make note of which terminals the 4 wires on the transformer go to and disconnect from transformer.
6. Using 9/32 nutdriver, remove the two transformer mounting nuts and lock washers.
7. Remove old transformer from studs and install new one. Reinstall nuts and lock washers.
8. Reconnect the 4 transformer wires.
9. Reinstall the control panel cover and the generator housing end cover.
10. Reinstall the fuses in the automatic transfer switch.
11. Put the generator selector switch back in "Automatic"
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!