the cover for the tray motor was attached to the bottom cover at 6 points. they were 3mm to 4mm long.
I used small wire cutter I use in fly tying hobby. The metal was easy to cut. When cover was removed I unplugged the motor,removed it and plugged the new one in.
To replace the cover -- reverse it,place the 2 tabs on one edge into the slots that are already part of the base. On the opposite edge there is a domed shaped tab with a hole in center. Place the small screw that was provided back in and thighten.
Your Done
To replace the cover -- reverse it,place the 2 tabs on one edge into the slots that are already part of the base. On the opposite edge there is a domed shaped tab with a hole in center. Place the small screw that was provided back in and thighten.
Your Done