Models > PD212D

PD212D Chamberlain Garage Door Opener

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for PD212D

Viewing 3 of 3
Keep searches simple, eg. "belt" or "pump".
This is a genuine OEM sourced part which is specially designed for Chamberlain garage door openers. It is an identical replacement for a missing or a faulty chain idler pulley that was installed on a ...
In Stock
Order now and your part arrives by Jun 1
This is a drive gear kit for various garage door openers, providing all the necessary parts to replace a malfunctioning gearbox that may cause difficulty in opening your garage door. If you notice pop...
Special Order
This is an authentic part produced by original manufacturer. It is used in various garage access systems by Chamberlain and LiftMaster. This assembly includes two (2) roll pins and one (1) each of: sp...
In Stock
Order now and your part arrives by Jun 1
It is a genuine item that is supplied by the original equipment manufacturer for use with Chamberlain and LiftMaster garage door openers. This is an identical replacement for a missing or a damaged li...
On Order
This is an authentic replacement part sourced directly from the manufacturer. The master link kit may be used with garage door opening systems from Chamberlain and LiftMaster. This kit contains part...
In Stock
Order now and your part arrives by Jun 1
In Stock
Order now and your part arrives by Jun 1
$49.66
This part is available as an individual replacement. The lens goes next to the end panel and is made of plastic. A screwdriver may be required to replace this item if it becomes broken. It is a genuin...
In Stock
Order now and your part arrives by Jun 1
Special Order
Special Order
In Stock
Order now and your part arrives by Jun 1
Special Order
In Stock
Order now and your part arrives by Jun 1

Questions and Answers

Ask our experts a question about this part and we'll get back to you as soon as possible!

1 question answered by our experts.
  • 1
Sort by:
Sorry, we couldn't find any existing answers that matched.
Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Dean
December 12, 2022
Garagedoor will open with the remote but not closed by remute. If you hold the cosole button it will close
For model number PD212D
Fix.com logo
Hi Dean, thank you for your inquiry. The problem is usually either due to a blocked path between the sensors, dirty safety eyes, loose wires at the sensors or at the motor head, bad sensors, or a bad motor control board. The transmitters (remotes) will not work to close the garage door if any of these issues are present. Also, try unplugging the garage door opener and re-plugging the unit back into the outlet. Check alignment on sensors, clean sensor eyes, check for damaged wiring, make sure wires are all connected well at the motor and sensors, unplug the motor and let it rest for a few minutes before replugging and testing again, clear memory on the motor, and reprogramming everything new. If it does not work, replace the motor control board, part number FIX12009868. Customer service is available 7 days a week if you require assistance placing an order. Thanks again for reaching out!