Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
CHARLOTTE from SEDALIA, MO
Parts Used:
297147700
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
replacement freezer keys
I accidently threw away both freezer keys to our upright Gibson and G.E. Freezers!!!! I had no luck finding replacements locally, so I got on the internet and came across PartSelect.com. I called them on the telephone; and after giving the model numbers of my freezers, the keys were on their way!! I received the keys very quickly and both worked perfectly. I would highly recommend Partselect.com. Charlotte M. Bishop
70 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Louise from Ocala, FL
Parts Used:
5304507200
Difficulty Level:
Easy
Total Repair Time:
1- 2 hours
Ice and frost were forming in a frost free freezer
The old gasket was obviously gapping, partially from age and partially from damage during a move. To make the repair, I loosened the screws that are under the gasket and hold it in, but did not remove them. Once all were loose, I removed the old gasket, then starting at the top, ran a thin bead of food grade RTV under the portion of the door that captures the gasket. I put the sealant on that edge only, then carefully worked one of the short edges of the gasket under the plastic and tightened all but the corner screws. I then ran the RTV down the inside of the hinge side of the door and repeated the process, this time tightening the top screw and the hinge side screw at the top, but leaving the bottom most screw loose. I repeated the process on the opening side of the door. The bottom was the hardest because the gasket seemed just a little long and it was hard to get the RTV up and behind the door portion, but after a couple tried I got a good bead of sealant then slid the gasket under the door capture and tightened all the remaining screws. After closing the door, it was obvious that there were places were it did not seal well. I used some cardboard strips, cut from the box the gasket came in, to place inside the freezer, between the hard plastic of the door and the inside of the gasket where it laps over the screws. This helped a lot, but there were still a couple small areas, so I used more cardboard, from the outside, between the main portion of the gasket and the rim of the gasket. This eliminated all the gaps. I let this sit overnight and this morning removed all the cardboard for a great sealing freezer.
75 of 97 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
John from Vancouver, WA
Parts Used:
297013500
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Rails for basket drawer were broken.
The repair was as easy as removing three phillip head screws for each slide rail and removing and replacing the broken slide rail. However, over the years, the walls of the freezer had bowed making the drawer a bit short to ride on the new rails -- causing the drawer to fall off the slide rails since the span between each rail was now wider than the basket. To remedy this problem. I used washers and placed them on the back side of each rail where the screws are located . This was the perfect solution compensating for the extra width resulting from the slightly bowed walls in the freezer. This solution allowed the basket to fit on each slide rail without falling off .
33 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
eric from inglewood, TN
Parts Used:
218909912, 5304491584
Difficulty Level:
A Bit Difficult
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Faulty Controller and Possibly Capacitor
After building a test box and determining the Controller was bad simply ordered parts and installed. Installation was a little difficult due to locking spades on electrical connections.

Unplug all power from freezer. Remove Bail wire from controller capacitor unit and remove from compressor by pulling STRAIGHT from compressor body to avoid bending contacts.

Use a very small instrumentation screwdriver to release locking spade on yellow and white wires. To unlock slide screwdriver in slot along wire entry to controller body while gently pulling on wire. Note position of wires and replace on new unit in same position/order. Plug new run capacitor into new controller being careful to orient capacitor to proper position (hole matches guide on controller unit). Plug newly installed controller and capacitor into condensor and replace bail wire.

Make sure timer is not in defrost mode - manually advance timer if necessary to ensure timer is in run mode. Turn temperature control to coldest setting. Plug in and hopefully enjoy the humming noise of your newly repaired and operational compressor and freezer.
33 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Paul from Cape Coral, FL
Parts Used:
297147700
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
The freezer door wouldn't stay shut due to two irresponsible children.
We ordered the part, which was a key, tied it on the freezer door handle, locked the door and voila, the problem was fixed. (We still have the children. :-)
24 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jorg from LOS ALAMOS, NM
Parts Used:
5304507200
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
replace a damaged door gasket
Removed old gasket by loosening all the screws. Inserted new gasket. Be careful to prop up the plastic shell so that ALL screw holes line up, especially at the bottom, and that shell is not tilted. Then carefully insert gasket inch by inch and fasten very other screw, best from bottom up. Make sure that the gasket lip is clearly under the shell and engaged with it. Before you do anything you have to straighten out ALL the kinks with a heat gun. Do not get too close. It takes a while.
14 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sophia from San Antonio, TX
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Defrost function in freezer was not working, while the refrigerating side was warm
1. Turned off and unplugged the refrigerator.
2. Removed the lower back panel inside the freezer with a screwdriver.
3. Unplugged the thermostat. (No tool is needed)
4. Ordered a new thermostat from PartSelect and it arrived in 2 business days.
5. Plugged in the new thermostat..
6. Put the lower back panel inside the freezer with screwdriver.
7. Plugged in the Refrigerator and turned the power back on.
8. It is working again!!!
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert H. from Grand Blanc, MI
Parts Used:
297216600
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Richard from Albuquerque, NM
Parts Used:
5304436055
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Fan Motor not working
Fist I removed the tow screws that hole the fan bracket - then remove the 2 screws that hole the fan-disconnect the wires and replace new unit.
13 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Robert from San Rafael, CA
Parts Used:
297147700
Difficulty Level:
Difficult
Total Repair Time:
Less than 15 mins
Lost Locked Freezer Door Key
Had to drag the full freezer out from the wall to expose the name plate, got the Model # and S/N and found the key on the partselect website in minutes. It was cheap so I got two. Other than FEDEX not knowing my address correctly, when I finally got the key it worked fine. Not a problem anymore.
Thanks
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Danielle from LAKEWOOD, CO
Parts Used:
297147700
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
Freezer Door Leaking
My issue was water leaking from the door. I thought it was the gasket, so I removed the gasket and the entire panel off of the door. There was water behind it that had soaked the cardboard seal, so I left that front part off for over a week to let it dry. We determined between us and our two toddlers that perhaps the door hadn't been properly closed enough on a number of occasions, so before I bought a $100 gasket, I'd try making sure the door was shut with tape, turning the freezer on and seeing what happened. There was no water after a few days, so on another user's suggestion I purchased the $15 key and twist tied it to the freezer door. Now I am locking the door after use so we won't have leaking water any longer.
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Kenneth from Safford, AZ
Parts Used:
218909912, 5304491584
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer compressor quit running causing freezer to defrost and ruin all contents.
Very simple repair. Removed the bail that holds the compressor controller and run capacitor from the compressor, removed the controller & capacitor, inserted a very small screwdriver into the controller to compress the barbs that hold the electrical wires to the controller. Plugged in the wires to the new controller in the same position as the original, plugged in the capacitor and then plugged the entire unit back onto the compressor, replaced the wire bail, plugged in the freezer and repair was complete.
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Elvin from Gardner, KS
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Nutdriver
defrost thermostat was open most of the time and didn't let the defrost element heat up.
Removed evaporator cover, unplug 2 wires to thermostat, unclipped it from the coil. Installed new themostat back the same way.
9 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Thomas from BATON ROUGE, LA
Parts Used:
5304507200
Difficulty Level:
Really Easy
Total Repair Time:
30 - 60 mins
Cannot be made
The called for part is the wrong size due a false correlation between the called for part number and the PartSelect number. I order twice and each time it was a 31 by 65 in. gasket not the appropriate 31 by 60 in.. Both were returned but no resolution.
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Matt from Cincinnati, OH
Parts Used:
297216600
Difficulty Level:
Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers
Freezer was freezing solid
I first replaced the defrost timer about a week prior and it did not correct the problem. I then ordered the thermostat from partselect and within 15 minutes had the part installed. My refridgerator has been running correctly for a couple weeks.
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25321741104