Customer:
Linda from Gurnee, IL
Parts Used:
216594300
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
The compressor would not run.
I removed the cover, used a multimeter to test the compressor circuit, and found the compressor start relay to be defective.
Ordered a new one and installed it when it arrived.
18 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Sherman from Tuttle, OK
Parts Used:
216594300
Difficulty Level:
Easy
Total Repair Time:
30 - 60 mins
Tools:
Screw drivers
Compressor was short cycling
Removed the cowling with a square drive screw driver, removed the spring clip from the cover of the compressor controls with a screw driver, pulled off the old compressor start relay and replaced it with the new part. Since other problems could have caused the compressor to short cycle this was a "replace the part and hope it would work" since that would be the most common reason and it was not a very expensive part.
12 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
judy from louisville, CO
Parts Used:
5303925379
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
One end cap on freezer door broke.
First removed the remaining end cap; then inserted rod into RH and LH replacement caps and snapped end caps into place.
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Lisa from Los Angeles, CA
Parts Used:
5303270406, 216594300
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Screw drivers
refrigerator stopped cooling
After the refrigerator stopped cooling, we determined that the problem was in the compressor area. we used a screwdriver to get the cover off and then vice grips to get the actual pieces out (start relay & overload)--they broke, but they were already broken). We went to the Home Depot site to purchase the parts, but found PartSelect to be much less expensive. Put the parts in when they came a few days later and it worked! thank you PartSelect!
11 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Tom from CEDARTOWN, GA
Parts Used:
216594300
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Freezer would not run ... replace the compressor start relay which fixed the problem
Pulled out the freezer. Unplugged. No freezer back cover was there. The compressor start relay was in a plastic encasement attached to the compressor - wires led me to it. Removed the solid metal spring with a screwdriver and removed the plastic cover. Tried to pull out the defective relay but the freezer was so old I needed a pliers to remove it. When I put pressure on the old relay with the pliers the relay broke and came off in pieces. I then removed the wires from the broken parts and put them on the new relay. I pushed the new relay onto the 2 pins then replaced the cover and spring. After plugging the freezer in the problem was fixed.
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
paul from LISLE, IL
Parts Used:
216502600
Difficulty Level:
Very Easy
Total Repair Time:
Less than 15 mins
While defrosting freezer tossed the drain plug with ice and water into the sewer system.
Opened mailer and bag and place the drain plug into the drain. fit perfectly. In fact it is better than the one lost since the original needed a screwdriver or tool to remove the plug. This one has a flang or finger turner on it so that it can be removed. Also, does not interfere with items in bottom of freezer.
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
James H from KNOXVILLE, TN
Parts Used:
3206256
Difficulty Level:
A Bit Difficult
Total Repair Time:
1- 2 hours
Tools:
Socket set
Ice crystals formed near gasket.
Removed the freezer door which had an electrical cord routed through the lower hinge with a disconnect under the freezer. Job works better with two people. Working the gasket into place was a little tricky at the corners. The putty knife was helpful. Make sure door is not warped when replaced on freezer. If warped slightly the door can be twisted to make gasket fit evenly bottom to top on front edge. Hope this helps DIY folks.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Andre from ANDERSON, SC
Parts Used:
216594300
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Screw drivers
Freezer was not freezing.
I removed the compressor start relay and replaced it with the new part. Initially it did not work. When I checked my work, I had to tighten the connector on the new part. Once I made the correction, the freezer is freezing normally again.
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!