Models > 87140-2

87140-2 General Electric Freezer

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for 87140-2

Viewing 3 of 3
Keep searches simple, eg. "belt" or "pump".
This 18 ml bottle of white appliance touch up paint is a little over two inches tall. It can be used for refrigerators, microwaves, ranges, clothes dryers, and freezers.
On Order
This part is both the start relay and the overload. The start relay boosts the compressor, and then shuts off as soon as the motor gets up to speed and the overload provides extra protection against e...
In Stock
Order now and your part arrives by May 26
In Stock
Order now and your part arrives by May 26
In Stock
Order now and your part arrives by May 26
This evaporator fan motor is located in the back of the freezer, and circulates air over the refrigerator coils. These coils will convert the heat into cool air, which is then circulated.
In Stock
Order now and your part arrives by May 26
In Stock
Order now and your part arrives by May 26
No Longer Available
No Longer Available
No Longer Available
12.50 X 27
No Longer Available
$24.00
In Stock
Order now and your part arrives by May 26
The thermostat senses that the heat near the cooling coils has reached the desired temperature.
No Longer Available

Questions and Answers

Be the first to ask our experts a question about this part!

Common Problems and Symptoms for 87140-2

Viewing 3 of 3
Won’t start
Fixed by these parts
Fixing
How to fix it
Too warm
Fixed by these parts
Fixing
How to fix it
Frost buildup
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
Kelly from Gladstone, OR
Parts Used:
5304442620
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
Freezer too warm
Removed two screws and wire harness from old motor. Put in new motor and connected wire harness.
17 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jerry from Elverta, CA
Parts Used:
WR09X10154
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Screw drivers
freezer kept icing up on the coils would only get down to 20 degrees.
unplug the freezer. remove the 2 screws holding the timer, unplug the electrical fitting w/4 prongs. reverse the steps and you are done.
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Customer:
Jim from Cherryvale, KS
Parts Used:
5304491584
Difficulty Level:
A Bit Difficult
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
Controller showed signs of the plastic housing had melted.
I paid attention to how the old part came off. You need a small (very small) flat bladed screwdriver to release the two wires that plug into the controller. I checked that it was a bit difficult but it would had been easier if I could have found a screwdriver sooner.
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?