Models > 45059A

45059A Frigidaire Freezer

Jump to:

Find Part by Name

Keep searches simple, eg. "belt" or "pump".

Diagrams for 45059A

Viewing 6 of 6
Keep searches simple, eg. "belt" or "pump".
$14.93
This multi-use screw fits various appliances and tools such as, freezers, refrigerators, wall ovens, washers, ranges, dishwashers, dryers, microwave oven combos, combos, wine and beverage coolers. *Pl...
In Stock
Order within the next 12 hrs and your part ships today!
Sold individually.
In Stock
Order within the next 12 hrs and your part ships today!
These are used to hold your gasket in place.
In Stock
Order within the next 12 hrs and your part ships today!
Refrigerant system filter/dryer.
In Stock
Order within the next 12 hrs and your part ships today!
No Longer Available
$168.69
In Stock
Order within the next 12 hrs and your part ships today!
Special Order
No Longer Available
In Stock
Order within the next 12 hrs and your part ships today!
$158.47
Special Order
This part provides protection for the compressor motor against excessive current and excessive temperature use.
No Longer Available
$11.44
Sold individually.
Special Order

Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

Common Problems and Symptoms for 45059A

Viewing 2 of 2
Frost buildup
Fixed by these parts
Fixing
How to fix it
Fridge too warm
Fixed by these parts
Fixing
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Customer:
FREDDIE from WHITAKERS, NC
Parts Used:
5303276514, 5303007173
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Pliers, Screw drivers
Freezer stopped freezing food.
I unplugged electrical cord to the freezer. I removed the cover to the relay and load protector. I labeled the wires and made a diagram on the proper placement of each wire going to the relay. I unplugged each wire and removed the relay. Then I removed the load protector. I installed the new load protector and new relay. I placed the wire s on the proper terminals of the relay. I replaced the electrical cover to the relay and load protector. I plugged the electrical cord back in the electrical outlet. My freezer started working again. I placed several bottles of water in the freezer to make sure the freezer was working properly before I restocked it with food.

Thanks again for the help. You just saved me about $400.
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!