Models
>
CFC09LW5
CFC09LW5 Crosley Freezer
Jump to:
Find Part by Name
Keep searches simple, eg. "belt" or "pump".
Diagrams for CFC09LW5
Viewing 3 of 3Keep searches simple, eg. "belt" or "pump".
In Stock
$11.98
This 18 ml bottle of white appliance touch up paint is a little over two inches tall. It can be used for refrigerators, microwaves, ranges, clothes dryers, and freezers.
On Order
$14.93
This multi-use screw fits various appliances and tools such as, freezers, refrigerators, wall ovens, washers, ranges, dishwashers, dryers, microwave oven combos, combos, wine and beverage coolers. *Pl...
In Stock
In Stock
In Stock
$64.56
The start relay briefly kick starts the compressor, and then shuts off as soon as the motor gets up to speed.
In Stock
In Stock
In Stock
In Stock
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
Common Problems and Symptoms for CFC09LW5
Viewing 5 of 5Won’t start
Fixed by these parts
How to fix it
Frost buildup
Fixed by these parts
How to fix it
Will Not Start
Fixed by these parts
How to fix it
Clicking sound
Fixed by these parts
How to fix it
Fridge too warm
Fixed by these parts
How to fix it
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Harry from Rockwall, TX
- Parts Used:
- 216954235
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Screw drivers
Refrigerator was trying to cycle compressor on, but each time the compressor started, it would stop due to the thermo breaker would open. The fans continued to run, so I figured it was starter relay.
Moved the refrig. out, removed the four screws that held the lower access panel in place. Disconnected the power cord. Removed the retainer clip wire and pulled the relays from the compressor socket. Separated the relays and installed the secondary relay on the new starter relay. Reinstalled the starter relay assembly into the compressor
... Read more
socket. Plugged the power cord in and listened for the compressor to cycle on. It cycled on and continued to run. Turned the power off and reinstalled the retainer clip wire. Reinstalled the access panel and plugged the power back in and left the refrig. run overnight. Checked temperature and also started the ice maker. Everything was normal by morning.
Read less
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Catrina from Calumet City, IL
- Parts Used:
- 297313200
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Screw drivers
Door wasn't closing correctly.
My husband removed the old hinge, by taking out the old screws and the old hinge and attached the new one, by inserting the new hinge and the new screws. It was as easy as 123.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Raymond from San Antonio, TX
- Parts Used:
- 216954235
- Difficulty Level:
- Easy
- Total Repair Time:
- 15 - 30 mins
- Tools:
- Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
Compressor would not start.
After earlier determing that the starter switch was at fault, I removed the cardboard lower back panel, shut off water to the ice maker, removed water line. The plug to the compressor containing the switch and capacitor was held on by a spring clip, removed clip pulled wires from old switch (Here needle nose pliars are handy as the spade
... Read more
clips on the 2 wires have their own locking clips) replaced switch and all wiring, tested unit and problem solved.
Read less