AQC2213TEW04 Amana Freezer - Instructions
Jump to:
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
- Customer:
- Mike from Baytown, TX
- Parts Used:
- W10309994
- Difficulty Level:
- Easy
- Total Repair Time:
- 1- 2 hours
- Tools:
- Nutdriver, Pliers, Wrench (Adjustable)
Compressor "grounded" and quit running
Replaced the compressor with the new one I purchased from you. Installed new parts and recharged unit. The refrigerator / freezer is working better than new. Thanks for the great deal on the compressor. It was here in 3 days. All the parts fit exactly and had no difficulty in the installation or startup. The directions for the wiring were a great help also. Thanks again.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Henry from Monrovia, CA
- Parts Used:
- W10917237
- Difficulty Level:
- Easy
- Total Repair Time:
- Less than 15 mins
- Tools:
- Pliers
light switch metal was corroaded by the moisture. there was no contact so light wouldnot turn on.
pulled switch from door ,unpluged it and then plued in new switch.
Was this instruction helpful to you?
Thank you for voting!
- Customer:
- Eric from VALLONIA, IN
- Parts Used:
- WP2183456
- Difficulty Level:
- Really Easy
- Total Repair Time:
- 30 - 60 mins
- Tools:
- Pliers, Screw drivers
Compressor would short cycle after overload tripped
Test original overload with meter to see if voltage drops out when overload trips. It did. Measured amp draw to verify compressor load was with in range, it was. New overload no longer trips during compressor start up.
Was this instruction helpful to you?